Kern ORA 3HB Käyttöohje

Lue alta 📖 käyttöohje suomeksi merkille Kern ORA 3HB (2 sivua) kategoriassa Mittauslaitteet. Tämä opas oli hyödyllinen 37 henkilölle ja sai 3.8 tähden keskimäärin 19 käyttäjältä

Sivu 1/2
1
2
CONTENTS
1 Technical data.................................................................................................1
2 Description......................................................................................................2
3 General information 3 .......................................................................................
3.1 Bestimmungsgemäße Verwendung 3 .............................................................
3.2 Warranty..........................................................................................................3
4 Basic safety information 4 ...............................................................................
4.1 Follow the instructions in the operating manual 4 .......................................
4.2 Warning ....................................................................................................... 4-5
5 Supplied items 5 ................................................................................................
6 Before the first use 6 ........................................................................................
7 Use/measurement.........................................................................................6
7.1 Zero point calibration 7-8 ................................................................................
7.2 Additional advice 9 ............................................................................................
7.3 Measuring procedure 9-10 ..............................................................................
8 Cleaning and maintenance 11 .........................................................................
9 Storage ......................................................................................................... 11
10 Service.......................................................................................................... 12
11 Disposal ........................................................................................................ 12
12 Additional information 12 ................................................................................
13 Brix to refractive index
(
)
conversion table 13 .........................................
14 Annex ............................................................................................................ 14
1. Technical data
Models
KERN
Measuring
range and
Scales
Scale
graduations
Accuracy
Dimensions
Product
Net weight
ORA 3 HBHA/
58-92% Brix
38-43°Bé
12-27% water
0,5% Brix
0,5°Bé
1 % water
160x40x40mm 0,140kg
ORA 6 HBHA/
12-30%
water content
in honey
0,1%
water content
in honey
168x40x40mm 0,140kg
Operating manual
Analogue refractometer
KERN & Sohn GmbH
KERN ORA 3 HB Baumé, Brix,HA/
honey moisture
ORA 6 HB Honey refractometerHA/
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-
[
0
]
7433-9933-0
Fax: +49-
[
0
]
7433-9933-149
Internet: www.kern-sohn.com
GB
2. Description
1. Prism cover
2. Prism surface
3. Adjustment screw
4. Eyepiece with rubber eyeshade
5. Diopter adjustment ring
6. Optical tubes with rubber grip
Example scale on
ORA 3 HB
1
6
3
5
4
2
Version 1.1 05 / 2016
7. Storage box
8. Pipette
9. Refractometer
10.
Contact liquid
(Clove oil)
11. Adjustment tool
12. Cleaning cloth
5
3
4
3. General information
3.1 Intended use
The refractometer is a measuring instrument for determining the refractive index of
transparent substances in the liquid or the solid state. It is used to observe the
behaviour of light as it passes from a prism with known properties to the substance
being tested.
Use of the refractometer for other purposes is contrary to its intended use and may
be hazardous. The manufacturer shall not be liable for any damages caused
by improper use.
3.2 Warranty
The warranty shall be void in the event of:
Failure to observe the instructions in the operating manual
Use for purposes other than those described
Modifications or opening the device housing
Mechanical damage and/or damage resulting from media, liquids,
natural wear and tear
4. Basic safety information
4.1 Follow the instructions in the operating manual
▸ Carefully read through the operating manual even if you have prior
experience with KERN refractometers.
Every language version includes a non-authoritative translation.
The original German document is the definitive version.
4.2 Warning
Do not let acids come into contact with skin or eyes. If acid comes into contact
with skin, flush with copious amounts of water. Shower if larger areas of skin are
affected.
If acid comes into contact with eyes, keep the eyelid open and flush the eye with
running lukewarm water from the outer corner to the inner corner. Flush eyes for
at least 15 minutes. Then consult a doctor or ophthalmologist immediately.
Thoroughly clean the refractometer aer each use.
The refractometer must not be exposed to extreme temperatures, high
mechanical stresses, strong direct sunlight or high humidity.
This refractometer is not a toy. Keep out of reach of children.
Make sure that you will not be hit by anything else while you are using the
refractometer, as this could cause serious eye injuries
The rubber eyeshade may cause irritation when in prolonged contact with the
skin. If this happens, consult your doctor.
Do not touch the lenses with your fingers.
6. Before the first use
Remove the protective film
(
if present
)
from the prism surface
[
2
]
and check that
the rubber eye-cup
[
4
]
is fitted correctly.
7. Use/measurement
The refractometer can be used to quickly and accurately determine the refractive
index of transparent substances, liquid or solid ones. To ensure correct measure-
ment, the measuring device should be adjusted before measurements are carried
out. Please make sure your hands are dry before handling the measuring device.
5. Supplied items
Aer unpacking and before using the device for the first time, check that all
listed parts have been supplied. Replace damaged or faulty parts immediately
and do not put them into operation.
Refractometer
Storage box
Pipette
Adjustment tool
▸ Cleaning cloth
Calibration block + Contact liquid ( )Clove oil
!
6
Avoid bringing the supplied contact liquid (clove oil) into contact with the prism
cover [1]. Even the smallest amounts of clove oil will damage the material of the
cover and lead to its opacification.
Therefore, pay big attention to this aspect while carrying out the adjustment of the refractometer
described below.
If still there is accidentally contact between clove oil and the prism cover, it would not affect
subsequent measurement operations even when high opacification occurs.
Important!