1. Technical data
Models
KERN
Measuring
range and
Scales
Scale
Accuracy
Dimensions
Product
Net weight
ORA 10 BBBA/
0-10 % Brix 0,1 % Brix 189x40x40mm 0,155kg
ORA 18 BB
0-18 % Brix 0,1 % Brix 189x40x40mm 0,155kg
ORA 20 BBBA/
0-20 % Brix 0,1 % Brix 189x40x40mm 0,155kg
ORA 32 BBBA/
0-32 % Brix 0,2 % Brix 178x40x40mm 0,145kg
ORA 80 BB
0-80 % Brix 0,5 % Brix 137x40x40mm 0,135kg
Operating manual
Analogue Brix Refractometer
KERN & Sohn GmbH
KERN ORA 10 ORA 32 BA/BB BA/BB
ORA 18 BB ORA 80 BB
ORA 20 BBBA/
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-
[
0
]
7433 - 9933-0
Fax: +49-
[
0
]
7433 - 9933-149
Internet: www.kern-sohn.com
GB
2. Description
1. Prism cover
2. Prism surface
3. Adjustment screw
4. Eyepiece with rubber eyeshade
5. Diopter adjustment ring
6. Optical tubes with rubber grip
Example scale on
ORA 18 BB
2
4
5
3
6
1
Version 1. 0 / 2012 4 9
CONTENTS
1 Technical data.................................................................................................1
2 Description......................................................................................................2
3 General information 3 .......................................................................................
3.1 Intended use 3 ...................................................................................................
3.2 Warranty..........................................................................................................3
4 Basic safety information 4 ...............................................................................
4.1 Follow the instructions in the operating manual 4 .......................................
4.2 Warning ........................................................................................................4-5
5 Supplied items 5 ................................................................................................
6 Before the first use 6 ........................................................................................
7 Use/measurement ........................................................................................6
7.1 Zero point calibration 7-8 ................................................................................
7.2 Additional advice 9 ............................................................................................
7.3 Measuring procedure ...............................................................................9-10
8 Cleaning and maintenance 11 ........................................................................
9 Storage ........................................................................................................ 11
10 Service ........................................................................................................ 12
11 Disposal ........................................................................................................ 12
12 Additional information 12 ................................................................................
13 Brix to refractive index
(
nD
)
conversion table 13 .........................................
14 Annex ........................................................................................................ 14
7. Storage box
8. Pipette
9. Refractometer
10.
Calibration liquid
(Distilled water)
11. Adjustment tool
12. Cleaning cloth
6
5
3
4
3. General information
3.1 Intended use
The refractometer is a measuring instrument for determining the refractive index of
transparent substances in the liquid or the solid state. It is used to observe the
behaviour of light as it passes from a prism with known properties to the substance
being tested.
Use of the refractometer for other purposes is contrary to its intended use and may
be hazardous. The manufacturer shall not be liable for any damages caused
by improper use.
3.2 Warranty
The warranty shall be void in the event of:
Failure to observe the instructions in the operating manual
Use for purposes other than those described
Modifications or opening the device housing
Mechanical damage and/or damage resulting from media, liquids,
natural wear and tear
4. Basic safety information
4.1 Follow the instructions in the operating manual
▸ Carefully read through the operating manual even if you have prior
experience with KERN refractometers.
Every language version includes a non-authoritative translation.
The original German document is the definitive version.
4.2 Warning
Do not let acids come into contact with skin or eyes. If acid comes into contact
with skin, flush with copious amounts of water. Shower if larger areas of skin are
affected.
If acid comes into contact with eyes, keep the eyelid open and flush the eye with
running lukewarm water from the outer corner to the inner corner. Flush eyes for
at least 15 minutes. Then consult a doctor or ophthalmologist immediately.
Thoroughly clean the refractometer aer each use.
The refractometer must not be exposed to extreme temperatures, high
mechanical stresses, strong direct sunlight or high humidity.
This refractometer is not a toy. Keep out of reach of children.
Make sure that you will not be hit by anything else while you are using the
refractometer, as this could cause serious eye injuries
The rubber eyeshade may cause irritation when in prolonged contact with the
skin. If this happens, consult your doctor.
Do not touch the lenses with your fingers.
6. Before the first use
Remove the protective film
(
if present
)
from the prism surface
[
2
]
and check that
the rubber eye-cup
[
4
]
is fitted correctly.
7. Use/measurement
The refractometer can be used to quickly and accurately determine the refractive
index of transparent substances, liquid or solid ones. To ensure correct measure-
ment, the measuring device should be adjusted before measurements are carried
out. Please make sure your hands are dry before handling the measuring device.
5. Supplied items
Aer unpacking and before using the device for the first time, check that all
listed parts have been supplied. Replace damaged or faulty parts immediately
and do not put them into operation.
Refractometer
Storage box
Pipette
Adjustment tool
▸ Cleaning cloth
alibration Cliquid (Distilled water)
!
The refractometer cannot be used for the measurement of oil-based fluids.

Tuotetiedot

Merkki: Kern
Kategoria: Mittauslaitteet
Malli: ORA 10BA

Tarvitsetko apua?

Jos tarvitset apua merkille Kern ORA 10BA esitä kysymys alla ja muut käyttäjät vastaavat sinulle