EtherWAN TG103H-0802 Käyttöohje
EtherWAN
Verkkokortti/sovitin
TG103H-0802
Lue alta 📖 käyttöohje suomeksi merkille EtherWAN TG103H-0802 (2 sivua) kategoriassa Verkkokortti/sovitin. Tämä opas oli hyödyllinen 33 henkilölle ja sai 3.8 tähden keskimäärin 17 käyttäjältä
Sivu 1/2

TG103H Page 1
Copyright 2023 EtherWAN Systems, Inc. All Rights Reserved /3 3 10 /202
Installation Gui e
TG103H | Unmanaged PoE Ethernet Switch
Unpacking
Open the carton and unpack the items. Your package should include:
▪ One TG103H Switch
If any items are missing or damaged, notify your EtherWAN representative. If
possible, save the carton and packing material in case you need to ship or store
the switch in the future.
Equipment Needed
▪ Appropriate cables for data ports. To prevent damage to the switch from
electrical surges, it is recommended to use STP (Shielded twisted pair) cabling
with a minimum rating of cat5e.
▪ Appropriate SFP modules for SFP ports
Select a Location
▪ Installation: Place the device on the DIN rail from above using the slot. Push
the front of the device toward the mounting surface until it audibly snaps into
place.
▪ Choose a dry area with ambient temperature between -40°C to 75°C (-an
40°F to 167°F).
▪ Keep away from heat sources, sunlight, warm air exhausts, hot-air vents, and
heaters.
▪ Be sure there is adequate airflow.
▪ Pollution degree 2.
Connect to the Data Ports
The switch the following ports: has
TG103H-0802
8 Gigabit PoE ports + 2 100/1G SFP ports
Connect Power
The switch has two power inputs. Only one power input is required to operate
the switch. Connect the supply voltage to start up the device via the terminal
block.
Power rating:
▪ PoE 30 Watts per port: 52 57 VDC, 5.47-4.99 A –
▪ PoE 9 Watts per port: 54 57 VDC, 17-0 –5. 4.99 A
▪ PoE power budget: 270W
▪ The power input specification complies with the requirements of SELV (Safety
Extra Low Voltage), and the power supply should comply with UL 61010-1
and UL 61010-2-201.
Terminal Block
The switch provides two power inputs on a -57VDC terminal block. 52
Pin
State
Description
Power 1
+
52-57VDC
-
Power Ground
Power 2
+
52-57VDC
-
Power Ground
Earth Terminal
Relay Output Rating
0.5A @ 48VDC
Relay Output Alarm
The switch provides a relay output contact. The relay is used to indicate user-a
defined power redundancy failure. The current is 0.5A@48VDC at Normal Open ly
or Normal Closed. ly
Relay Contact
Normally Open
Normally Closed
No power
Open
Closed
Normal
Closed
Open
Abnormal
Open
Closed
LED Indicators
TG103H-0802
LED
Color
Status
L/A (Link/Active)
Green
On: Link active
Off: No l ink
Flashing: Data transmission
PWR 1 & 2
Green
On: Power on
Off: Power off
Alarm
Red
On: Error - power redundancy
failure
Off: No power error condition
PoE
Amber
On: Powered Device connected
Off: Powered Device disconnected
Power-Up Sequence
When the switch is powering up:
▪ All Link/ACT LEDs blink momentarily.
▪ The Power 1, 2 LEDs light up and stay lit.
▪ LEDs for every port connected to a device will flash, as the switch conducts a
brief Power On Self-Test (POST).
Quality of Service (QoS)
The QoS feature is automatically activated when the switch is running. Priority
mapping is handled according to the following tables:
CoS priority
(802.1p)
7, 6
5, 4
3, 2
1, 0
DSCP priority
59, 55
47, 46, 43
27
Other
Queues
3
2
1
0
WFQ
Highest
Priority
Secondary
Priority
16
1
EtherNet/IP: UDP 2222 (Queue 2)
Profinet Ether type: 0x8892 (Queue 2)
DIP Switch Settings
There is a 10-pin DIP switch for enabling the PoE Watchdog function.
When the DIP switch for a port is set to ON, the watchdog function will be
enabled after the device has been powered on for 10 minutes to give powered
devices time to boot. Every 30 seconds, the device will detect whether the
packets from a powered device are being received or not. If no packet is received
after 30 seconds, connected ports with the DIP switch set to ON will be restarted
(other ports are not disturbed). If a packet is received in the 25th second, then
the 30 second interval will be restarted.
If DIP switch 9 (EXT) is set to ON, the watchdog function will be enabled after 5
minutes instead of 10 minutes after the switch powers on.
Tuotetiedot
| Merkki: | EtherWAN |
| Kategoria: | Verkkokortti/sovitin |
| Malli: | TG103H-0802 |
Tarvitsetko apua?
Jos tarvitset apua merkille EtherWAN TG103H-0802 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Verkkokortti/sovitin EtherWAN Käyttöohjeet
3 Huhtikuuta 2025
2 Huhtikuuta 2025
28 Tammikuuta 2025
Verkkokortti/sovitin Käyttöohjeet
- Verkkokortti/sovitin Ditek
- Verkkokortti/sovitin NUVO
- Verkkokortti/sovitin SMK-Link
- Verkkokortti/sovitin Martin Logan
- Verkkokortti/sovitin Panamax
- Verkkokortti/sovitin Vivotek
- Verkkokortti/sovitin Netgear
- Verkkokortti/sovitin StarTech.com
- Verkkokortti/sovitin Joy-it
- Verkkokortti/sovitin Sonnet
- Verkkokortti/sovitin OpenVox
- Verkkokortti/sovitin Twelve South
- Verkkokortti/sovitin Hamlet
- Verkkokortti/sovitin Strong
- Verkkokortti/sovitin ZyXEL
Viimeisimmät Verkkokortti/sovitin Käyttöohjeet
8 Huhtikuuta 2025
3 Huhtikuuta 2025
2 Huhtikuuta 2025
1 Huhtikuuta 2025
30 Maaliskuuta 2025
29 Maaliskuuta 2025
14 Maaliskuuta 2025
14 Maaliskuuta 2025
12 Maaliskuuta 2025
10 Maaliskuuta 2025