For additional self-service support options and community forums, please visit: www.StarTech.com/support
Revision: August 29, 2024
Quick-Start Guide
Product ID
CABSHELFV2U-16-RACK
CABSHELFV2U-12-RACK
CABSHELFV1U-16-RACK
Feature Function
1
Brackets
Used to fasten the to the of a Shelf Mounting Posts Server
Rack
2Shelf Surface Place Server Rack Equipment
3Ventilation Holes Promote airow for the Server Rack Equipment
Package Contents
2-Post Vented Shelf x1
M5 Cage Nuts x 4
M5 Screws x 4
Quick-Start Guide x 1
Vented 2-Post Shelf
Requirements
For the latest manuals, product information, technical specications, and declarations of
conformance, please visit:
www.StarTech.com/CABSHELFV2U-16-RACK
www.StarTech.com/CABSHELFV2U-12-RACK
www.StarTech.com/CABSHELFV1U-16-RACK
Refer to the manufacturer of the Server Rack to determine the mounting hole type and
size
Phillips head screwdriver
Cage nut tool (Optional)
Warnings!
Read the entire Quick-Start Guide and ensure the instructions are fully understood before
using this product.
Before adding equipment to this product, ensure this product has been properly mounted.
Never operate this product if parts are missing or damaged.
Ensure the weight of the equipment does not exceed the weight capacity of this product. If
the weight capacity is exceeded, personal injury or damage to the equipment is possible.
These product can support the following weight:
CABSHELFV2U-16-RACK: 44lb / 20kg
CABSHELFV2U-12-RACK: 25lb / 11.3 kg
CABSHELFV1U-16-RACK: 30lb / 14kg
Installation
1. Identify a suitable location on the to mount the . The requires Server Rack Shelf Shelf
2U 1U Mounting Space or of (depending on the model).
Note: The Server Rack should have enough Mounting Depth to accommodate the Shelf.
2. Install the (x 4) into the (x 4) on the of the M5 Cage Nuts Mounting Holes Front Posts
Server Rack Cage Nut Tool . If available, use a or a preferred installation method to
install the . Cage Nuts
Note: If the Server Rack has M5 threaded holes, skip this step. The M5 Screws can be
installed without the M5 Cage Nuts.
Use the manufacturer-recommended Screws for the Server Rack if they dier from M5.
3. Position the onto the at the chosen , determined inShelf Server Rack U Height
*Product may vary from image
1
2
3
1

Tuotetiedot

Merkki: StarTech.com
Kategoria: Ei luokiteltu
Malli: CABSHELFV2U-12-RACK

Tarvitsetko apua?

Jos tarvitset apua merkille StarTech.com CABSHELFV2U-12-RACK esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Ei luokiteltu StarTech.com Käyttöohjeet

Ei luokiteltu Käyttöohjeet

Viimeisimmät Ei luokiteltu Käyttöohjeet