READ CAREFULLY.
KEEP THESE INSTRUCTIONS
.
Installation Built-In Trim Kits
Instructions
JX2027 and JX2030
Read these instructions completely and carefully.
IMPORTANT
Save these instructions for local inspector’s use.
IMPORTANT
Note to Installer Be sure to leave these instructions with the
Consumer.
Note to Consumer Keep these instructions for future reference.
For easier installation and personal safety, we recommend that two people
install this microwave oven.
WARNING
This oven must be plugged into a properly
grounded 3-hole, 120V receptacle as required by the National Electrical Code
or the Canadian Electrical Code.
BEFORE YOU BEGIN
Do not alter or modify any part of this kit or the oven.
Unplug the microwave oven before attempting installation of this kit.
Skill level Installation of this appliance requires basic mechanical and
electrical skills.
Completion time 1-3 hours
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
This kit is UL/CSA listed for installation alone or over any GE/GE Profile
single electric wall oven. Not for use adjacent to (within 2 feet of) any gas
or electric range, cooktop or oven.
This kit is for use on models: PEB2060DMBB, PEB2060DMWW,
PEB2060DMCC, PEB2060SMSS, JEB1860DMBB, JEB1860DMWW,
JEB1860DMCC, JEB1860SMSS, PEB206CDNBB, PEB206CSNSS,
PEB206CDNWW, JEB186CDNWW, JEB186CDNBB and JEB186CSNSS.
TOOLS YOU WILL NEED
Phillips screwdriver
Pencil
Tape measure
Awl or punch
Drill with
7
64bit or #35
FOR YOUR SAFETY:
WARNING
Before beginning the
installation, switch power off at service panel and lock
the service disconnecting means to prevent power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the
service panel.
Level
Scissors (optional)
1
PART QUANTITY
Trim Frame 1
Bottom Duct 1
Side Duct 1
4 mm x 12 mm 23
Round-Head Screws (21 required
for installation)
4 mm x 14 mm 6
Flat-Head Screws
(4 required for
installation)
Anti-Tip Brace 1
Anti-Tip Bracket 1
Upper Duct 1
Top Bracket 1
Bottom Bracket 1
Templates 2
PARTS INCLUDED
NOTE: This kit has extra screws to prevent the technician from spending extra
time locating a replacement screw in case they lose one during installation.
Questions? In the U.S., call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com.
In Canada, call 1.800.561.3344 or Visit our Website at: GEAppliances.ca.