Extron XTP PI 100 Käyttöohje
                    Extron
                    
                    Verkkokortti/sovitin
                    
                    XTP PI 100
                
                                
                
                
                                
                Lue alta 📖 käyttöohje suomeksi merkille Extron XTP PI 100 (2 sivua) kategoriassa Verkkokortti/sovitin. Tämä opas oli hyödyllinen 41 henkilölle ja sai 4.3 tähden keskimäärin 21 käyttäjältä
                        Sivu 1/2
                    
                    
                    
1
XTP PI 100 (60-1233-01, 28-156-07LF) 
Power Supply • Installation Guide
The Extron XTP PI 100 Power Injector supplies power to one XTP® Series extender, 
IP Link Pro control processor, MediaLink® Plus controller, or TouchLink® Pro 
touchpanel. This guide provides instructions for an experienced installer to install 
and connect the XTP PI 100.
XTP
PWR
XTP PWR
100-240V 50/60 Hz
0.4A MAX
Rear Panel Front Panel
Installation
Step 1 — Mounting
ATTENTION:
•  These power supplies are not suitable for use in air handling spaces or in 
wall cavities. The power supply must be located within the vicinity of the 
Extron AV equipment in an ordinary location with pollution degree2, and 
secured to an equipment rack within a dedicated closet, podium, or desk.
•  Ces sources d’alimentation ne sont pas appropriées pour une utilisation 
dans les espaces d’aération ou dans les cavités murales. Cette source 
d’alimentation doit être située à proximité de l’équipement audiovisuel 
d’Extron, dans un endroit ordinaire avec une pollution IEC1010 degré2, 
et xé à un équipement de rack au sein d’un placard, d’une estrade ou 
d’un bureau qui lui est dédié.
•  The installation must be in accordance with the applicable provisions 
of National Electrical Code ANSI/NFPA70, article725 and Canadian 
Electrical Code part1, section16. The power supply must not be 
permanently xed to building or similar structure.
•  Cette installation doit toujours être en accord avec les mesures qui 
s’applique au National Electrical Code ANSI/NFPA70, article725, et au 
Canadian Electrical Code, partie1, section16. La source d’alimentation 
ne devra pas être xée de façon permanente à une structure de bâtiment 
ou à une structure similaire.
•  The PI 140 is intended for indoor use only. No part of the network that 
uses XTP remote power can be routed outdoors.
•  LePI140 est destiné à une utilisation en intérieur seulement. Aucune 
partie du réseau qui utilise l’alimentation XTP à distance ne peut être 
routée en extérieur.
Using the ZipClip 200
To attach the power supply to the ZipClip 200 mounting clip:
1.  Insert the bottom of the power supply down into the clip, starting with one end.
2.  Pivot the other end down and press until the clip  
snaps into place.
To remove the power supply from the ZipClip:
1.  Press the tab (1) on the ZipClip.
2.  Pivot the power supply and lift it out of the 
ZipClip (2).
To fasten the tie wraps for cable strain relief:
1.  Attach the power supply to the  
ZipClip 200 mounting clip as described 
previously.
2.  Fasten the power output cords to the 
ZipClip base.
a.  Insert tie wraps along the notches on 
the side of the power supply and through the tie 
wrap anchor points on the ZipClip, then around 
the cord.
b.  Connect and pull the tie wraps until they are 
secure. Do not over tighten.
Mounting to a Rack Shelf
These power supplies are one-quarter rack 
wide. Up to four power supplies can be 
mounted side by side directly onto a rack shelf.
1.  Align the threaded holes in 
the bottom of the power 
supply with the holes in an 
Extron rack shelf. Fasten 
the supply to the shelf 
with two 4-40 x 3/16 inch 
screws (1) as shown on 
the right.
2.  Bolt the rack shelf to the rack (2).
Furniture Mounting
NOTE: The ZipClip is shipped with 
a set of four wood screws.
1.  Attach the ZipClip to the furniture 
using two or more wood screws as 
shown at right (1). Make sure the clip 
is oriented with the appropriate side 
facing the mounting surface and with 
the tab accessible from the front of 
the furniture.
2.  Insert the power supply into the 
ZipClip as described previously and 
press to snap it into place (2).
(2) 4-40 x 3/16"
Sc srew
RSB  312
Rack Shelf
Ra  Mountedck
1
2
100-240V 
~
 50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
Tie Wrap
XTPPI100
ZipClip 200
100-240V 
~
 50-60Hz
0
.4A MA
X
100-240V 
~
 50-60Hz
0
.4A 
MAX
XTP
PWR
XTP PWR
1
2
Mounting to Rack Rails Using a ZipClip
1.  Fasten the ZipClip 200 mounting clip to a rack rail 
using two rack screws as shown in the diagram on 
the right.
2.  Insert the bottom of the power supply down into  
the clip, starting with one end.
3.  Pivot the other end toward the clip and press until 
the clip snaps into place.
ZipClip 200
Ba  of Rackck
1
2
NOTE: Do not use two power injectors on the same cable run to remotely 
power the transmitter and receiver. The diagram below shows this type of 
application, which is not recommended by Extron.
POWE R
12V
INPUT S
2
--A MAX
RxT x
RS- 232  IR
RxT x
1NET
SIG                 LINK
ACT                 LINK
XT P OUT
OVE R  XTP
AUDIO
CONT ACT RS - 232
T x  Rx
XTP  T  USW 10 3
31   2   3
RES ET
LAN
ACT               LINK
SIG                 LINK
XT P IN
POWE R
12V
OUT PUT S
HDMI
-- A MAX
RxT x
RS -23 2  IR 
RxT x −+ −+
L R 1 2
OVER  XTP
AUDIO
OFF
HDMI AUDIO
ON
S/PD IF
RELAYS
XTP  SR HDMI
RES E T
REMOT E
RS- 2 32
T x Rx
XTP
PWR
XTP  PWR
100-240V 50/60 Hz
0.4A MAX
XTP
PWR
XTP  PWR
100-240V 50/60 Hz
0.4A MAX
CATx
XTP SR HDMI
CATx
CATx 
XTP T  3USW 10
  P  0XT PI 10
XTP  0PI 10
NOT RECOMMENDED
Important Safety Instructions
This symbol, when used on the product, is intended 
to alert the user of important operating and 
maintenance (servicing) instructions in the literature 
provided with the equipment.
This symbol, when used on the product, is intended 
to alert the user of the presence of uninsulated 
dangerous voltage within the product enclosure 
that may present a risk of electric shock.
  •  Read these instructions.
  •  Keep these instructions.
  •  Heed all warnings.
  •  Follow all instructions.
  •  Do not use this apparatus near water.
  •  Clean only with a dry cloth.
  •  Do not block any ventilation openings. Install in accordance with the 
manufacturer instructions.
  •  Do not install near any heat sources such as radiators, heat registers, 
stoves, or other apparatus (including amplifiers) that produce heat.
  •  Do not defeat the safety purpose of the polarized or grounding-type 
plug. A polarized plug has two blades with one wider than the other.  A 
grounding type plug has two blades and a third grounding prong. The 
wide blade or the third prong is provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement 
of the obsolete outlet.
  •  Protect the power cord from being walked on or pinched, particularly at 
plugs, convenience receptacles, and the point where they exit from the 
apparatus.
  •  Use only attachments and accessories specified by the manufacturer.
  •  Unplug this device apparatus during lightning storms or when unused 
for long periods of time.
CAUTION: Risk of electric shock. To reduce the risk 
of fire or electric shock, do not expose this apparatus to rain, 
moisture, dripping, splashing, or objects filled with liquids.
ATTENTION: Risque de choc électrique: Afin de 
réduire les risques d’incendie ou de choc électrique, protégez 
cet appareil de la pluie ou de l’humidité. Cet appareil doit être 
conservé à l’abri des éclaboussures et des projections, et aucun 
objet contenant un liquide, tel qu’un vase, ne doit être posé sur 
l’appareil.
Refer all servicing to qualified service personnel. Servicing is required 
when the apparatus has been damaged in any way, such as when 
the power-supply cord or plug is damaged, liquid has been spilled 
or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been 
dropped.
ATTENTION:
•  This apparatus is a Class I product. This product must be 
connected to a mains socket outlet with a protective earthing 
connection.
•  Cet appareil est un produit de Classe1. Ce produit doit 
être connecté à une prise femelle secteur équipée d’une 
connexion de mise à la terre.
The mains plug is used as the disconnect device and shall remain readily 
operable.
To prevent the risk of shock, do not attempt to service this equipment 
yourself because opening or removing covers may expose you to 
dangerous voltage or other hazards.
ATTENTION:
Power sources • This equipment should be operated only from 
the power source indicated on the product. This equipment is 
intended to be used with a main power system with a grounded 
(neutral) conductor. The third (grounding) pin is a safety feature. 
Do not attempt to bypass or disable it.
[Source d’alimentation] • Ce matériel ne devrait être alimenté 
qu’à partir de la source d’alimentation stipulée sur le produit. 
Ce matériel est prévu pour être relié à un circuit d’alimentation 
général doté d’un conducteur (neutre) mis à la terre. La troisième 
broche (de terre) est un composant de sécurité. N’essayez pas 
de l’éviter ou de la désactiver.
Power disconnection • To remove power from the equipment safely, 
remove all power cords from the rear of the equipment, or the 
desktop power module (if detachable), or from the power source 
receptacle (wall plug).
Déconnection de l’alimentation • Pour déconnecter le matériel de 
sa source d’alimentation en toute sécurité, débranchez tous les 
cordons d’alimentation de l’arrière du matériel ou débranchez 
l’adaptateur secteur (si débranchable) ou de la prise secteur 
(prise murale).
LED Indicators
A Front panel power LED indicator — 
Lights to indicate the XTP PI 100 is  
receiving power.
B Rear panel PWR LED indicator — 
Indicates various power states of the 
connected endpoints (see the table below).
LED State Port Status
Unlit The endpoint is not connected or cannot be powered.
Lit The endpoint is receiving power from the XTP PI 100.
Blinks ve times There is a power overload fault.
Blinks nine times The power allocation is exceeded.
NOTE: The blinking LED repeats the specified number of blinks from the 
table above after a short interval of remaining unlit.
Step 2 — Cabling
ATTENTION:
 zDo not connect these devices to a computer data or 
telecommunications network.
 zNe connectez pas ces appareils à des données informatiques ou à un 
réseau de télécommunications.
For the best performance, see Twisted Pair Recommendations on page 2.
1.  Connect a network switch, XTP extender, IP Link Pro control processor, or 
MediaLink Plus controller to the XTP  
port (A) of the power injector using a 
straight-through cable. The device 
plugged into this connector needs to 
be powered by a local power source.
2.  Connect an XTP extender, IPL Pro, 
MLC Plus, or TouchLink Pro 
touchpanel that requires remote 
power to the XTP Pwr port (B)  
using a straight-through cable.
3.  Connect AC power to the XTPPI100 (C).
XTP
PWR
XTP PWR
100-240V 50/60 Hz
0.4A MAX
A
B
100-240V 
~
 50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To Network or 
XTP device
To XTP, IPL Pro, 
MLC Plus, or TLP Pro 
device that can be 
powered via  EPo
AB
C
Tuotetiedot
| Merkki: | Extron | 
| Kategoria: | Verkkokortti/sovitin | 
| Malli: | XTP PI 100 | 
Tarvitsetko apua?
Jos tarvitset apua merkille Extron XTP PI 100 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Verkkokortti/sovitin Extron Käyttöohjeet
                        
                         16 Lokakuuta 2024
                        
                    
                                                            Verkkokortti/sovitin Käyttöohjeet
- Verkkokortti/sovitin Vigitron
- Verkkokortti/sovitin Edimax
- Verkkokortti/sovitin Hamlet
- Verkkokortti/sovitin AViPAS
- Verkkokortti/sovitin TP Link
- Verkkokortti/sovitin NUVO
- Verkkokortti/sovitin Rocstor
- Verkkokortti/sovitin Apc
- Verkkokortti/sovitin EVOLVEO
- Verkkokortti/sovitin EtherWAN
- Verkkokortti/sovitin Digitus
- Verkkokortti/sovitin OpenVox
- Verkkokortti/sovitin Louroe Electronics
- Verkkokortti/sovitin Mikrotik
- Verkkokortti/sovitin Martin Logan
Viimeisimmät Verkkokortti/sovitin Käyttöohjeet
                        
                         8 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         2 Huhtikuuta 2025
                        
                    
                                                            
                        
                         2 Huhtikuuta 2025
                        
                    
                                                            
                        
                         1 Huhtikuuta 2025
                        
                    
                                                            
                        
                         30 Maaliskuuta 2025
                        
                    
                                                            
                        
                         29 Maaliskuuta 2025
                        
                    
                                                            
                        
                         14 Maaliskuuta 2025
                        
                    
                                                            
                        
                         14 Maaliskuuta 2025