WARNINGCAUTION
Read through this Installation Manual before installing.
WARNING
Installer must apply for standard installation guidance.
• Please perform the installation work, select insulation, and perform heat insulation construction in accordance with
the laws and regulations of each country.
• For specifications of connection piping, refer to Table 1 below.
• Piping is limited to newly installed piping.
Even with newly installed piping, remove places to which brazing material is adhered, or which have been burnt the burner.by
• Please keep minimum wall thickness of the pipe for installation.
• Do not disassemble the GAS TIGHT JOINT.
• When rk working in high places, womust be performed with a stable scaffold.
• Carry out the work of connecting the GAS TIGHT JOINT one location at a timemaking sure each location is secure.,
(Do not perform simultaneous work on 2 or more locations between the same outdoor and indoor unit)
• Do not use the GAS TIGHT JOINT which has been dropped.
•
The GAS TIGHT JOINT cannot be re-used if it has already been inserted into the piping, temporarily fixed, and removed.
•
Do not turn the nut in the loosening direction.
INSTALLATION MANUAL
SDGTB06
·
09
·
12
·
15
·
19
·
22
·
28
SDGTB0906
·
1209
·
1512
·
1915
·
2219
·
2522
·
2825
·
3428
BDGTA34
·
41, SDGTLB22
·
28
3V022006-1A
GAS TIGHT JOINT
The case which may cause
dangerous situation such as
death or severe injury, at the
same time, it may cause
property damage when
mis-operated.
The case which may cause
dangerous situation such as
injury or minor injury, at the
same time, it may cause
property damage when
mis-operated.
R410A, R32 UNIT ONLY
Removing the thermal insulation
material (copper pipe)
1
1) Be careful not to damage the pipe.
2) If using insulated copper pipe, cut in a
cylindrical direction, not in a lengthwise
direction.
(Cylindrical direction)
(Lengthwise direction)
R32: Type BDGTA34/41 are not applicable in the EU
Table 1 : Specication of connection piping
Standard
ASTM B280ASTM B88 (Type L)EN12735
Model name
Size (O.D.)O60H58Thickness (mm)
O60
O50
H58R220R250R290Thickness (mm)Thickness (mm)
Same diameterDifferent diameter
SDGTB06
SDGTB0906
–
φ6.35
–
0.762±0.08
–––
––
0.80±0.08
1.00±0.13
SDGTB09
SDGTB1209
φ9.52
–
0.813±0.08
–
0.762±0.08
–
0.80±0.08
––
1.00±0.13
SDGTB12
SDGTB1512
φ12.7
–
0.813±0.08
–
0.889±0.11
––
0.80±0.08
–
–
0.91±0.09
–
1.00±0.13
SDGTB15
SDGTB1915
φ15.88
–
0.889±0.11
–
1.016±0.11
–
–
0.91±0.09
–
1.00±0.13
SDGTB19
SDGTB2219
φ19.05
–
1.07±0.10
–
1.07±0.11
–
1.00±0.13
–
–
1.25±0.19
SDGTB22
SDGTLB22SDGTB2522
φ22.22
–
1.14±0.10
–
1.14±0.11
––
1.00±0.13
–
–
1.25±0.19
1.63±0.25
–
SDGTB2825
φ25.4 *2
–––––––
–
1.00±0.13
SDGTB28
SDGTLB28
SDGTB3428
φ28.58
–
1.27±0.10
–
1.27±0.13
–
1.00±0.13
1.25±0.19
–
–
1.63±0.25
BDGTA34
–
φ34.92
–
1.40±0.15
–
1.40±0.15
–
1.25±0.19
–
–
1.63±0.25
BDGTA41
––
φ41.28
–
1.52±0.15
–
1.52±0.15
–
1.25±0.19
––
1.63±0.25
Notes) 1. “–” : No settings
2. *2 : For connection to the stop valve outlet pipe only.
Tuotetiedot
| Merkki: | Daikin |
| Kategoria: | Kattilat ja kattilat |
| Malli: | SDGTB06 |
Tarvitsetko apua?
Jos tarvitset apua merkille Daikin SDGTB06 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Kattilat ja kattilat Daikin Käyttöohjeet
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
15 Helmikuuta 2025
11 Helmikuuta 2025
1 Helmikuuta 2025
5 Tammikuuta 2025
5 Tammikuuta 2025
5 Tammikuuta 2025
21 Joulukuuta 2024
Kattilat ja kattilat Käyttöohjeet
Viimeisimmät Kattilat ja kattilat Käyttöohjeet
1 Huhtikuuta 2025
31 Maaliskuuta 2025
13 Maaliskuuta 2025
10 Maaliskuuta 2025
10 Maaliskuuta 2025
27 Helmikuuta 2025
27 Helmikuuta 2025
27 Helmikuuta 2025
27 Helmikuuta 2025
27 Helmikuuta 2025