Daikin 5MWXM90A2V1B9 Käyttöohje

Lue alta 📖 käyttöohje suomeksi merkille Daikin 5MWXM90A2V1B9 (80 sivua) kategoriassa Kattilat ja kattilat. Tämä opas oli hyödyllinen 21 henkilölle ja sai 3.7 tähden keskimäärin 11 käyttäjältä

Sivu 1/80
Installer reference guide
R32 Split series
5MWXM68A2V1B9
5MWXM90A2V1B9
Table of contents
Installer reference guide
2
5MWXM-A9
R32 Split series
4P766272-3A – 2024.10
Table of contents
1 About the documentation 4
1.1 About this document...................................................................................................................................................... 4
1.1.1 Meaning of warnings and symbols................................................................................................................ 5
2 General safety precautions 7
2.1 For the installer .............................................................................................................................................................. 7
2.1.1 General........................................................................................................................................................... 7
2.1.2 Installation site............................................................................................................................................... 8
2.1.3 Refrigerant — in case of R410A or R32......................................................................................................... 11
2.1.4 Electrical......................................................................................................................................................... 12
3 Specific installer safety instructions 15
4 About the box 20
4.1 Outdoor unit................................................................................................................................................................... 20
4.1.1 To unpack the outdoor unit........................................................................................................................... 20
4.1.2 To handle the outdoor unit ........................................................................................................................... 20
4.1.3 To remove the accessories from the outdoor unit ....................................................................................... 21
5 About the unit 22
5.1 Identification .................................................................................................................................................................. 22
5.1.1 Identification label: Outdoor unit.................................................................................................................. 22
6 Unit installation 23
6.1 Preparing the installation site ........................................................................................................................................ 23
6.1.1 Installation site requirements of the outdoor unit ....................................................................................... 24
6.1.2 Additional installation site requirements of the outdoor unit in cold climates ........................................... 26
6.2 Opening the unit ............................................................................................................................................................ 27
6.2.1 About opening the unit.................................................................................................................................. 27
6.2.2 To open the outdoor unit .............................................................................................................................. 27
6.3 Mounting the outdoor unit............................................................................................................................................ 28
6.3.1 About mounting the outdoor unit................................................................................................................. 28
6.3.2 Precautions when mounting the outdoor unit ............................................................................................. 28
6.3.3 To provide the installation structure............................................................................................................. 28
6.3.4 To install the outdoor unit............................................................................................................................. 29
6.3.5 To provide drainage....................................................................................................................................... 29
6.3.6 To prevent the outdoor unit from falling over.............................................................................................. 30
7 Piping installation 31
7.1 Preparing refrigerant piping........................................................................................................................................... 31
7.1.1 Refrigerant piping requirements................................................................................................................... 31
7.1.2 Refrigerant piping insulation ......................................................................................................................... 32
7.1.3 Refrigerant piping length and height difference........................................................................................... 33
7.2 Connecting the refrigerant piping.................................................................................................................................. 34
7.2.1 About connecting the refrigerant piping ...................................................................................................... 34
7.2.2 Precautions when connecting the refrigerant piping ................................................................................... 35
7.2.3 Guidelines when connecting the refrigerant piping ..................................................................................... 36
7.2.4 Pipe bending guidelines................................................................................................................................. 37
7.2.5 To flare the pipe end ..................................................................................................................................... 37
7.2.6 Connections between outdoor and indoor unit using reducers .................................................................. 37
7.2.7 Using the stop valve and service port ........................................................................................................... 40
7.2.8 To connect the refrigerant piping to the outdoor unit................................................................................. 41
7.2.9 To install sound insulation............................................................................................................................. 42
7.3 Checking the refrigerant piping ..................................................................................................................................... 42
7.3.1 About checking the refrigerant piping .......................................................................................................... 42
7.3.2 Precautions when checking the refrigerant piping....................................................................................... 42
7.3.3 To check for leaks .......................................................................................................................................... 43
7.3.4 To perform vacuum drying ............................................................................................................................ 43
8 Charging refrigerant 45
8.1 About charging refrigerant............................................................................................................................................. 45
8.2 About the refrigerant ..................................................................................................................................................... 46
8.3 Precautions when charging refrigerant ......................................................................................................................... 47
8.4 To determine the additional refrigerant amount.......................................................................................................... 47
8.5 To determine the complete recharge amount.............................................................................................................. 48
8.6 To charge additional refrigerant .................................................................................................................................... 48
8.7 To fix the fluorinated greenhouse gases label............................................................................................................... 48
Table of contents
Installer reference guide
3
5MWXM-A9
R32 Split series
4P766272-3A – 2024.10
8.8 To check refrigerant piping joints for leaks after charging refrigerant......................................................................... 49
9 Electrical installation 50
9.1 About connecting the electrical wiring.......................................................................................................................... 50
9.1.1 Precautions when connecting the electrical wiring...................................................................................... 50
9.1.2 Guidelines when connecting the electrical wiring........................................................................................ 52
9.1.3 Specifications of standard wiring components............................................................................................. 53
9.2 To connect the electrical wiring to the outdoor unit .................................................................................................... 54
10 Finishing the outdoor unit installation 56
10.1 To finish the outdoor unit installation ........................................................................................................................... 56
10.2 To close the outdoor unit............................................................................................................................................... 56
11 Configuration 57
11.1 About standby electricity saving function ..................................................................................................................... 57
11.1.1 To turn ON standby electricity saving function............................................................................................. 57
11.2 About priority room function......................................................................................................................................... 58
11.2.1 To set the priority room function.................................................................................................................. 58
11.3 About night quiet mode................................................................................................................................................. 58
11.3.1 To turn ON the night quiet mode.................................................................................................................. 58
11.4 About heat mode lock.................................................................................................................................................... 59
11.4.1 To turn ON heat mode lock ........................................................................................................................... 59
12 Commissioning 60
12.1 Overview: Commissioning.............................................................................................................................................. 60
12.2 Precautions when commissioning ................................................................................................................................. 60
12.3 Checklist before commissioning .................................................................................................................................... 61
12.4 Checklist during commissioning..................................................................................................................................... 62
12.5 Trial operation and testing............................................................................................................................................. 62
12.5.1 About wiring error check............................................................................................................................... 62
12.5.2 To perform a test run .................................................................................................................................... 63
12.6 Starting up the outdoor unit .......................................................................................................................................... 64
13 Hand-over to the user 65
14 Maintenance and service 66
14.1 Overview: Maintenance and service.............................................................................................................................. 66
14.2 Maintenance safety precautions ................................................................................................................................... 66
14.3 Checklist for yearly maintenance of the outdoor unit .................................................................................................. 67
14.4 About the compressor ................................................................................................................................................... 67
15 Troubleshooting 68
15.1 Overview: Troubleshooting............................................................................................................................................ 68
15.2 Precautions when troubleshooting................................................................................................................................ 68
15.3 Solving problems based on symptoms .......................................................................................................................... 68
15.3.1 Symptom: Indoor units fall, vibrate or make noise....................................................................................... 68
15.3.2 Symptom: The unit is NOT heating or cooling as expected.......................................................................... 69
15.3.3 Symptom: Water leakage .............................................................................................................................. 69
15.3.4 Symptom: Electrical leakage.......................................................................................................................... 69
15.3.5 Symptom: Priority room setting does NOT function .................................................................................... 69
15.3.6 Symptom: Unit does NOT function or burn damage .................................................................................... 69
15.4 Solving problems based on LED behaviour.................................................................................................................... 69
15.4.1 Fault diagnosis using LED on outdoor unit PCB ............................................................................................ 69
16 Disposal 71
16.1 Overview: Disposal ......................................................................................................................................................... 71
16.2 To pump down ............................................................................................................................................................... 71
16.3 To start and stop forced cooling .................................................................................................................................... 72
17 Technical data 73
17.1 Wiring diagram ............................................................................................................................................................... 73
17.1.1 Unified wiring diagram legend ...................................................................................................................... 73
17.2 Piping diagram: Outdoor unit ........................................................................................................................................ 75
18 Glossary 78

Tuotetiedot

Merkki: Daikin
Kategoria: Kattilat ja kattilat
Malli: 5MWXM90A2V1B9

Tarvitsetko apua?

Jos tarvitset apua merkille Daikin 5MWXM90A2V1B9 esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Kattilat ja kattilat Daikin Käyttöohjeet

Kattilat ja kattilat Käyttöohjeet

Viimeisimmät Kattilat ja kattilat Käyttöohjeet