WHALE AquaSmart Käyttöohje
                    WHALE
                    
                    Vesipumppu
                    
                    AquaSmart
                
                                
                
                
                                
                Lue alta 📖 käyttöohje suomeksi merkille WHALE AquaSmart (2 sivua) kategoriassa Vesipumppu. Tämä opas oli hyödyllinen 41 henkilölle ja sai 4.7 tähden keskimäärin 21 käyttäjältä
                        Sivu 1/2
                    
                    
                    
Carbon  Filter
(Product
  Code  WF3000)
AQUASMART
®
 WATER  SYSTEM
AQUASMART
®
 WATER SYSTEM – TROUBLE SHOOTING
Munster Simms Engineering Ltd.
2 Enterprise Road, Bangor, N. Ireland BT19 7TA  Tel: +44 (0)28 9127 0531 Fax: +44 (0)28 9146 6421
Web: www.whalepumps.com  Email: info@whalepumps.com
Ref No: 180.39_v5_0114
Please  read  carefully  before  use.
To  the  Fitter:
Ensure  all  relevant  personnel  read  and  that  a  copy  is  passed
on  to  the  end  user.
To  the  User:
Read  the  user  guide  overleaf  before  use  of  equipment.
SERVICE  KITS
Service  kits  are  available  from  Whale  dealers  worldwide.    To
ensure  correct  service  kits,  check  Whale  website
www.whalepumps.com  or  contact  Whale  service  desk:  Email:
info@whalepumps.com.
REPLACING  FILTERS
A  pack  containing  two  replacement  filters  (Product  Code
WF3000)  is  available.    Filters  will  need  to  be  replaced  after
filtering  3000  litres  (approx.  33  days  of  normal  use).    These
filters  are  not  designed  for  removing  bacteria  and  should  not
be  used  on  water  supplies  of  an  unknown  bacterial  quality.
Plug  and  Hose  Assembly
with  Dust  Cover
(UH0814)
Dust
Cover
  Whale  Quick
Connect  Fitting
(WU1204)
  Whale  Quick
Connect  12mm
tubing
(WX7112)
Watermaster  On
Board  Pump
(FP0814)
 STANDARD SYSTEM
  3-Way
Solenoid
Valve
  Whale  Quick
Connect
Fitting
(WU1202)
ELECTRIC  SYSTEM  FOR  USE
WITH  ONBOARD  TANKS
  2-Way
Solenoid
Valve
  ON-BOARD  TANK
  ON-BOARD  TANK
MANUAL  SYSTEM  FOR  USE
WITH  ON-BOARD  TANKS
3-Way
Valve
(WU1271)
  Take  care  to  retain  the  o-ring  seal  when  replacing  filters
Wall
Socket
FAULT  CAUSE  SOLUTION 
No power to pump 
Check power supply 
Attach leads/ clean connections 
Check tap microswitch is present 
Fuse has blown  Replace fuse – do not exceed recommended fuse size 
Pump doesn’t run 
Blockage in pipework  Check pipework for kinks 
No water getting to pump 
Check water tank is not empty 
Check filter is not blocked 
Check filter is fully submerged in water 
Check all connections from tank to inlet of pump are 
secure, any leaks will prevent prime. 
To test for air leaks hold showerhead underwater and 
operate pump. If air bubbles visible coming from the 
showerhead then leak is present 
Pump runs but no water 
appears 
Water leak at outlet side of pump 
Check pipework and fittings for leaks and repair 
Check system drain plugs are closed 
Water leak at outlet side of pump 
Check pipework/ fittings for leaks and repair 
Check system drain plugs are closed 
Pump runs but will not switch 
off 
No water 
Check water supply level 
Check and replace filter if clogged 
Pump cycles on and off 
periodically when all the taps 
are closed (Normal with 
partially opened tap) 
Water leaking at outlet side of pump 
Check pipework/ fittings for leaks and repair 
Check system drain plugs are closed 
Pump cycles on and off 
excessively when tap(s) open 
Excessive back pressure 
Check pipework for kinks and filters etc. are clear 
Check shower rose & taps for blockages and repair 
Pump drawing air  See CAUSE ‘NO water getting in pump’ 
Noisy Operation 
Noise created by vibration 
Check pump is secured to a solid surface 
Check pump body is clear of hard surfaces 
Locate away from interfering surfaces 
Check pipework is securely supported 
Bore of pipework / connections too 
small 
8.5mm minimum bore recommended for pipework 
(Whale Quick Connect 12mm tubing – Product code 
WX7112 blue/cold and WX7114 red/hot) 
Check for kinks in pipework 
Check pipework is not blocked 
Power supply to the pump 
Check power supply to pump uses correct wire 
(2.5mm
2
) to give full voltage at pump 
Check battery is not flat 
Pipework/ Connections crushed due to 
over tightened jubilee clips 
Replace damaged connections 
Pump too far from water tank  Pump should be situated beside inlet/ water tank 
Water leaking at outlet side of pump 
Check pipework fittings for leaks and repair 
Check system drain plugs are closed 
Low flow 
Valves internal filters clogged (if 
present) 
Remove manual/ electric valve, inspect internal filters 
If necessary remove fitting nearest filter 
Clean and refit filter and plumbing 
Tuotetiedot
| Merkki: | WHALE | 
| Kategoria: | Vesipumppu | 
| Malli: | AquaSmart | 
Tarvitsetko apua?
Jos tarvitset apua merkille WHALE AquaSmart esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Vesipumppu WHALE Käyttöohjeet
                        
                         18 Lokakuuta 2024
                        
                    
                                                            
                        
                         18 Lokakuuta 2024
                        
                    
                                                            
                        
                         18 Lokakuuta 2024
                        
                    
                                                            
                        
                         18 Lokakuuta 2024
                        
                    
                                                            Vesipumppu Käyttöohjeet
- Vesipumppu Global
- Vesipumppu Grundfos
- Vesipumppu Nibe
- Vesipumppu Pontec
- Vesipumppu Elpumps
- Vesipumppu DAB
- Vesipumppu T.I.P.
- Vesipumppu Rinnai
- Vesipumppu Heissner
- Vesipumppu Einhell
- Vesipumppu Yellow Garden Line
- Vesipumppu Vonroc
- Vesipumppu Fieldmann
- Vesipumppu Prowork
- Vesipumppu Duro Pro
Viimeisimmät Vesipumppu Käyttöohjeet
                        
                         1 Huhtikuuta 2025
                        
                    
                                                            
                        
                         1 Huhtikuuta 2025
                        
                    
                                                            
                        
                         1 Huhtikuuta 2025
                        
                    
                                                            
                        
                         1 Huhtikuuta 2025
                        
                    
                                                            
                        
                         29 Maaliskuuta 2025
                        
                    
                                                            
                        
                         28 Maaliskuuta 2025
                        
                    
                                                            
                        
                         27 Maaliskuuta 2025
                        
                    
                                                            
                        
                         27 Maaliskuuta 2025
                        
                    
                                                            
                        
                         27 Maaliskuuta 2025
                        
                    
                                                            
                        
                         27 Maaliskuuta 2025