Installation & Operation
UPS
Product Overview
Fault Code Table
1. Inspection
The following items are inside the box: UPS Unit, User Manual
Remove the UPS from its package and inspect it for damage that may have occurred during
shipping. If any damage is discovered, re-pack the unit and return it to the place of purchase.
2. Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start to charge inside battery. For best
result, charge the battery for 6 hours prior to initial use.
3. Plug in Equipment
Battery back-up Outlets (5)
Connect computer and monitor to the “Battery Backup” outlets. These outlets provide battery
backup, EMI ltering, line conditioning, and surge protection. Battery power is automatically
provided in case of power failure.
Surge-Protected Outlets (5)
Connect a printer, fax machine, or scanner to the “Surge-protected” outlets. These outlets do not
provide power during power failure.
CAUTION: NEVER connect a laser printer or scanner to the battery backup sockets of UPS. The
equipment may draw signicantly power to overload the UPS
4. Turn On/Othe UPS
To turn on the UPS unit, hold the power button until you hear a beep. To turn o the UPS unit,
hold the power button until it beeps. Then, display will shut o.
1. LCD display or LED indicators
(Please check LCD section for
the details)
2. Power Switch
3. Mute Button
4. Up/down button
5. AC Input
6. Circuit Breaker
7. Surge-protected outlets
8. Battery Backup Outlets
9. USB port (option)
10. Modem/phone/network surge
protection (option)
11. Coax surge protection (option)
Fault Condition SolutionsLCD
Output short circuited Disconnect short-circuited loads and
restart the UPS again
Inverter/Output failure Call for service immediately
Overcharge
1. Turn o the unit and wait for cooling.
2. Or remove excessive loads and wait
for cooling.
Note: If fault alarm occurs, please call for service immediately.
LED DISPLAY UPS1DT550-1N only
Operation Display
UPS Mode DescriptionLCD
UPS Power ON When UPS is powered on, all icons will
light up 1 second
Standby Mode
Site wiring fault in
standby mode Low Battery
AC Mode
When AVR is functioning,
icon will ash
every second.
Press button to switch displayed
information.
1. Output voltage
2. Output frequency
3. Input voltage
4. Input frequency
5. Output power in kW
6. Output power in kVA
7. Estimated backup time
Overload in AC mode
icon will ash
When overload occurs, alarm will beep
every 0.5 second.
Site wiring fault in AC
mode
Battery Mode
In battery mode, press
button to mute
alarm and icon will
be on.
Alarm will beep every 10 seconds and
LCD information will be displayed in the
following order when pressing
button.
1. Estimated backup time
2. Output voltage
3. Output frequency
4. Input voltage
5. Input frequency
6. Output power in kW
7. Output power in kVA
When battery level is low,
icon will ash
Alarm will beep every second. This alarm
can not be mute.
Overload in battery mode
icon will ash
When overload occurs, alarm will beep
every 0.5 second.
NOTE: The backlight will be always on when any fault or warning occurs.
5. Install software (Optional for advanced users)
For optimal computer system protection, install UPS monitoring software to fully congure the UPS
system. Please follow steps below to download and install monitoring software.
1. Go to the website http://www.V7-world.com/downloads
2. Select ViewPower software for your operating system to download the software.
3. Follow the on-screen instructions to install the software.
1
2
3
4
10
5 6
7 8
11
9