CONTENTS
NAMES OF PARTS
INDOOR UNIT DISPLAY
OPERATING INSTRUCTIONS
INSTALLATION MANUAL
MAINTENANCE
TROUBLESHOOTING
EMERGENCY FUNCTION & AUTO-RESTART FUNCTION
REMOTE CONTROLLER
................................................................................................................4
.......................................................................................................5
.............................................6
.......................................................................................................7
.............................................................................................11
....................................................................................................20
....................................................................................................................35
..........................................................................................................36
..................................................................................................1
SAFETY PRECAUTIONS

During the installation of the indoor and
outdoor units the access to the working area
should be forbidden to children.
Unforeseeable accidents could happen.
Make sure that the base of the outdoor unit is
firmly fixed.
Check that air cannot enter the refrigerant
system and check for refrigerant leaks when
moving the air con ditioner.
SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER
Carry out a test cycle after installing the air
conditioner and record the operating data.
The ratings of the fuse installed in the built
in control unit are 4A / 250V .
Protect the indoor unit with a fuse of suitable
capacity for the maximum input current or with
another overload protection device.
Ensure that the mains voltage corresponds to
that stamped on the rating plate. Keep the switch
or power plug clean. Insert the power plug
correctly and firmly into the socket, thereby
avoiding the risk of electric shock or fire due to
insufficient contact.
Check that the socket is suitable for the plug ,
otherwise have the socket changed.
Do not install the appliance at a distance of
less than 50 cm from inflammable substances
(alcohol, etc.) or from pressurised containers
(e.g. spray cans).
If the appliance is used in areas without the
possibility of ventilation, precautions must be
taken to prevent any leaks of refrigerant gas
from remaining in the environment and creating
a danger of fire
The packaging materials are recyclable and
should be disposed of in the separate waste
bins .Take the air conditioner at the end of its
useful life to a special waste collection centre
for disposal.
Only use the air conditioner as instructed in
this booklet. These instructions are not intended
to cover every possible condition and situation .
As with any electrical household appliance ,
common sense and caution are therefore always
recommended for installation, operation and
maintenance.
The appliance must be installed in accordance
with applicable national regulations.
Before accessing the terminals , all the power
circuits must be disconnected from the power
supply.
Read this guide before installing and using the
appliance.
1
The appliance must be fitted with means for
disconnection from the supply mains having a
contact separation in all poles that provide full
disconnection under overvoltage category III
conditions, and these means must be incorporated
in the fixed wiring in accordance with the wiring
rules.
The appliance shall be installed in accordance
with national wiring regulations.
This appliance can be used by children aaged
from 8 years and above and persons with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they
have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved. Children
shall not play with the appliance. Cleaning and
user maintenance shall not be made by
children without supervision.
The air conditioner must be installed by
professional or qualified persons.

SAFETY RULES AND RECOMMENDATIONS FOR THE USER
Do not try to install the conditioner alone;
always contact specialized technical personnel.
Cleaning and maintenance must be carried out
by specialized technical personnel. In any case
disconnect the appliance from the mains
electricity supply before carrying out any
cleaning or maintenance.
Ensure that the mains voltage corresponds to
that stamped on the rating plate. Keep the switch
or power plug clean. Insert the power plug
correctly and firmly into the socket , thereby
avoiding the risk of electric shock or fire due
to insufficient contact.
Do not pull out the plug to switch off the
appliance when it is in operation, since this
could create a spark and cause a fire, etc.
If the appliance gives off smoke or there is a
smell of burning, immediately cut off the pow
er supply and contact the Service Centre.
Have repairs carried out only by an authorised
Service Centre of the manufacturer . Incorrect
repair could expose the user to the risk of
electric shock, etc.
The prolonged use of the device in such
conditions could cause fire or electrocution.
Never remain directly exposed to the flow of
cold air for a long time. The direct and prolonged
exposition to cold air could be dangerous for your
health .Particular care should be taken in the
rooms where there are children , old or sick
people.
This appliance has been made for air
conditioning domestic environments and must
not be used for any other purpose , such as for
drying clothes, cooling food, etc.
The packaging materials are recyclable and
should be disposed of in the separate waste
bins . Take the air conditioner at the end of its
useful life to a special waste collection center
for disposal.
Only use the air conditioner as instructed in
this booklet. These instructions are not intended
to cover every possible condition and situation.
As with any electrical household appliance,
common sense and caution are therefore always
recommended for installation , operation and
maintenance.
Always use the appliance with the air filter
mounted . The use of the conditioner without
air filter could cause an excessive accumulation
of dust or waste on the inner parts of the device
with possible subsequent failures.
Unhook the automatic switch if you foresee
not to use the device for a long time.
The airflow direction must be properly adjusted.
The user is responsible for having the appliance
installed by a qualified technician , who must
check that it is earthed in accordance with current
legislation and insert a thermomagnetic circuit
breaker.
Ensure that the appliance is disconnected from
the power supply when it will remain inoperative
for a long period and before carrying out any
cleaning or maintenance.
Selecting the most suitable temperature can
prevent damage to the appliance.
The flaps must be directed downwards in
the heating mode and upwards in the cooling
mode.
The batteries in remote controller must be
recycled or disposed of properly.
Disposal of Scrap Batteries --- Please discard
the batteries as sorted municipal waste at the
accessible collection point.
2

SAFETY RULES AND PROHIBITIONS
3
Do not bend , tug or compress the power cord
since this could damage it. Electrical shocks or
fire are probably due to a damaged power cord.
Specialized technical personnel only must replace
a damaged power cord.
Do not use extensions or gang modules.
Do not touch the appliance when barefoot or
parts of the body are wet or damp.
Do not obstruct the air inlet or outlet of the
indoor or the outdoor unit.
The obstruction of these openings causes a
reduction in the operative efficiency of the
conditioner with possible consequent failures
or damages.
In no way alter the characteristics of the
appliance.
Do not install the appliance in environments
where the air could contain gas , oil or sulphur
or near sources of heat.
Do not climb onto or place any heavy or hot
objects on top of the appliance.
Do not leave windows or doors open for long
when the air conditioner is operating.
Do not direct the airflow onto plants or
animals.
A long direct exposition to the flow of cold
air of the conditioner could have negative
effects on plants and animals.
Do not put the conditioner in contact with
water.
The electrical insulation could be damaged
and thus causing electrocution.
Do not climb onto or place any objects on the
outdoor unit
Never insert a stick or similar object into the
appliance. It could cause injury.
This appliance is not intended for use by
persons (including children ) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure
that they do not play with the appliance.
If the supply cord is damaged, it must be
replaced by the manufacturer,its service
agent or similarly qualified persons in
order to avoid a hazard.

INDOOR UNIT DISPLAY
5
The shape and position of switches and indicators may be different according to the model, but their
function is the same.
2
No.
Led Function
1
2
3
Temperature display (if present)
/Error code
(1) Lights up during Timer operation when
the air conditioner is operational
(2)Displays the malfunction code when
fault occurs.
SLEEP mode
Lights up during Timer operation.
SLEEP
TIMER
3
1

7
REMOTE CONTROLLER
TCL TCL
For ON/OFF models For inverter models

9
REMOTE CONTROLLER
Remote controller DISPLAY, meaning of symbols on the liquid crystal display
1
2
3
4
5
6
7
8
9
10
11
12
13
14
AUTO MODE indicator
COOLING MODE indicator
DRY MODE indicator
FAN MODE indicator
HEATING MODE indicator
TIMER indicator
AUTO FAN indicator
FAN SPEED indicator
SLEEP MODE indicator
FLAP SWING (Air flow) indicator
15
TURBO indicator
16
17
HEALTHY indicator
18
ECO indicator
Meaning
No. Symbols
TEMPERATURE/ CLOCK indicator
BATTERY indicator
19
I FEEL indicator
20
MUTE indicator
(FLASH)
or
8 C heating function indicator
GENERATOR MODE indicator
21
22
CHILE ROCK indicator
GENTLE WIND indicator
CHILL WIND indicator
HOT WIND indicator
DISPLAY LIGHT indicator
CLEAN function indicator
23
24
25

10
Replacement of Batteries
Remove the battery cover plate from the rear of the remote controller,
by sliding it in the direction of the arrow.
Install the batteries according the direction (+and -)shown on the Remote
Controller.
Reinstall the battery cover by sliding it into place.
Use 2 LRO 3 AAA (1.5V) batteries . Do not use rechargeable
batteries . Replace the old batteries with new ones of the same
type when the display is no longer legible.
Do not dispose batteries as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
Recommendations for locating and using the remote controller holder (if present).
The remote controller be kept in a wall-mounted holder.

OPERATING INSTRUCTIONS
Filter
Heat
Fan
Exchanger
11
The direction of the air outlet is motorized up and down
by flaps, and manually moved right and left by the vertical
deflectors, for some models, the vertical deflectors could be
controlled by motor as well.
The air sucked by the fan enters from the grill and
passes through the filter, then it is cooled/dehumidified
or heated through the heat exchanger.
Fan
Turn ON / Turn OFF the air conditioner
Press the button to turn on or turn off the air conditioner.
COOLING MODE
The cooling function allows the air condit-
ioner to cool the room and at the same time
reduces Air humidity.
To activate the cooling function ( COOL ) , press the
MODE button until the symbol appears on
the display.
With the button or set a temperature lower than
that of the room.

13
OPERATING INSTRUCTIONS
Horizontal Flaps
flap
movement Vertical Deflectors
AIR FLOW CONTROL
Never position Flaps manually, the delicate
mech-anism might seriously damaged!
Never poke fingers, sticks or other objects in the
air inlet or outlet vents. Such accidental contact
with liveparts might cause unforeseeable damage
or injury.
This adjustment must be done while the
appliance is switched off.
1. Normal 4 way air flow (vertical and horizontal):
(1) Press to activate the horizontal flaps to
swing from up to down. Press again to stop the swing
movement at the current angle.
(2) Press to active the vertical deflectors to
swing from left to right. Press again to stop the swing
movement at the current angle.
2. Vector precise air flow
(1)Press and hold for 1s, it will go into the horizontal
vector air flow, you can select a small swing angle you
want:
Stop selection for 5s, press again, exit the horizontal vector precise air flow.
(2) Press and hold for 1s, it will go into the vertical
vector air flow:
Stop selection for 5s, press again, exit the vertical vector precise air flow.
3. If the vertical deflectors are positioned manually whichplaced under the flaps, they are allowed to move
the air flow direct to rightward or leftward.
Change the fan speed
Press FAN button to set the running fan speed, it can
be set to AUTO/ MUTE/ LOW/ MID-LOW/ MID/ MID-HI/
HIGH/TURBO speed.
Flashing

14
OPERATING INSTRUCTIONS
GENTLE WIND (Optinal)
In this mode the appliance will close its
vertical louvers, the air flow through the holes
of louvers, the room is cool but no winds.
Press the GENTLE WIND button shortly, the appears on
the display, and the appliance will run in GENTLE WIND mode.
Press again to cancel it..
NOTE:
The gentle wind function is available in COOLING mode only.
I FEEL function
I FEEL
Press I FEEL button to active the function, the
will appear on the remote display.
Do it again to deactivate this function.
This function enables the remote control to measure
the temperature at its current location, and send this
signal to the air conditioner to optimize the temperature
around you and ensure the comfort.
It will automatically deactivate 2 hours later.
Turbo function
To activate turbo function, press the TURBO button,
and will appear on the display.
In COOL/HEAT mode, when you select TURBO
feature, the appliance will operate the fast cooling/
fast heating with the highest fan speed.
Press again to cancel this function.

OPERATING INSTRUCTIONS
15
SLEEP MODE
Pre-setting automatic operating program.
After 10 hours running in sleep mode, the air conditioner
will change to the previous setting mode.
Press SLEEP button and hold for 2s to activate the sleep
mode, and appears on the display.
Press and hold for 2s again to cancel this mode.
In sleep mode, the air conditioner will automatically adjust
the temperature and fan speed to make the room more
comfortable during the night.
The air conditioner works in generator mode,
it is helpful for the unstable net power area.
To activate GEN function,pressing the button GEN and
the unit current level will cycle as below
OFF L3 L2 L1
To cancel this function,press the GEN until code OF
appers on the display.
Through GEN mode,you can choose the current level of
the unit.There are three levels (L1,L2,L3) in this mode,
and the current increases in turn.
GENERATOR MODE (Optional)
Running current (% of rated current):
L1: 30%, L2: 50%, L3:70%
ECO MODE
In this mode the appliance automatically
sets the operation to save energy.
Press the ECO button, the appears on the
display, and the appliance will run in ECO mode.
Press again to cancel it..
NOTE:
The ECO function is available in both COOLING and
HEATING modes.

OPERATING INSTRUCTIONS
16
LED display light ON/OFF
Press DISPLAY button and hold for 2s to turn on/off
the indoor LED display light.
HEALTH function (Optional)
Press HEALTH button to active / exit the health functions
such as ion generator/ plasma etc
Note: Health function is not available when the air conditioner
is off.
1. This function help carry away the accumulated
dirt, bacteria, etc from the evaporator.
2. Turn off the air conditioner, press "CLEAN" button to enter
this function and it will show "CL" on the display of indoor unit.
3. This function will run about 30 minutes, and it will exit
automatically.You will hear 2 beeps when it's finished or
cancelled.
4. It's normal if there are some noise during this function
process, as plastic materials expand with heat and
contract with cold.
5.We suggest operate this function as the following ambient
condition to avoid certain safety protection features.
6. We suggest operate this function once every 3 months.
Indoor unit
Outdoor unit
Temp<30
5 <Temp<30
SELF-CLEAN function (Optional)

OPERATING INSTRUCTIONS
17
TIMER MODE----SET TIMER OFF
TIMER
To set the air conditioner switching-off
automatically.
With the AC off, press the Timer button and use the
and buttons to set the desired amount of time before the
AC turns on. Press the timer button again to start the countdown.
When the timer setting was done, you can set the operation mode,
fan speed, desired temperature, air flow when air conditioner star
to run.
Note:To cancel the setted function, press the TIMER
button again.
Note:In case of power off,it is necessary to set TIMER
OFF again
TIMER MODE----SET TIMER ON
TIMER
Note: To cancel the timer function ,press the TIMER
button again.
Note: In case of power off, it is necessary to set TIMER
ON again
With the AC on, press the Timer button and then use the
and buttons to set the length of time before the AC will
turn off. Press the timer button again to start the countdown.
To set the air conditioner switching-on
automatically.

OPERATING INSTRUCTIONS
In each mode of COOLING/HEATING/FAN/DRY, adjust the
temperature(COOLING/HEATING), fan speed (COOLING/
HEATING/FAN)and swing as your favourite, then keep
pressing "I SET" button over 3 seconds until "AU" appears
on the display and the background of display change to
lighting, the remote controller will run and remember
these settings. You can reset it by repeat the above operation.
In each mode of COOLING/HEATING/FAN/DRY, press "I SET"
button to active this function, the AC will run as your
favourite setting and you will see AU flashing on the
remote controller. Press it again or other buttons to
cancel this function.
I SET function(Optional)
18
CHILL wind/ HOT wind function (Optional)
8 heating function (Optional)
1.Press both ECO/DISPLAY and HEALTH/CLEAN buttons and
hold for 2s to active the 8 heating.
2.If the air conditioner is standby, this function enable the
air conditioner automatically start heating when the
indoor temperature is equal or lower than 8 , it will return
standby if the temperature is equal or higher than 18 .
1. In cooling mode, press both TIMER/SLEEP and ECO/DISPLAY
buttons and hold for 2s to active the chill wind function.
2. In heating mode, press both TIMER/SLEEP and ECO/DISPLAY
buttons and hold for 2s to active the hot wind function.
3. Press both TIMER/SLEEP and ECO/DISPLAY buttons and hold
for 2s to exit the chill wind or hot wind function.
3.When the AC was turn off, press both ECO/DISPLAY and
HEALTH/CLEAN buttons and hold for 2s to exit the 8 heating.

19
The air conditioner is programmed for comfortable and suitable living conditions as below
if used outside the conditions, certain safety protection features might come into effect.,
OPERATING INSTRUCTIONS
Operating Temperature
Fix air conditioner:
MODE
Temperature
Room temperature
Outdoor
temperature
Cooling operating Heating operating Drying operating
17 ~32 0 ~27 17 ~32
15 ~43
For T1 Climate
15 ~52
For T3 Climate
-7 ~24
Inverter air conditioner:
MODE
Temperature
Room temperature
Outdoor
temperature
Cooling operating Heating operating Drying operating
17 ~32 0 ~30 17 ~32
15 ~53
-15 ~53
For models with low
temperature cooling
system
-20 ~30
The unit does not operate immediately if it is turned on after being turned off or after changing
the mode during operation.This is a normal self-protection action,you need waiting for about 3
minutes.
The capacity and efficiency are according to the test conducted at full-load operation(The
highest speed of indoor fan motor and the maximum open angle of the flaps and deflectors
are requested.)
15 ~43
For T1 Climate
15 ~52
For T3 Climate
15 ~53
-15 ~53
For models with low
temperature cooling
system

INSTALLATION MANUAL---Important considerations for R32/R290
21
The maximum charge and the required minimum floor area
3 3 3
m = (4 ) x m LFL , m = (26 m)) x LFL, m = (130 m )x LFL
1 2 3
3 3 3
Where LFL is the lower flamm
For the appliances with a charge amount m < = :M m
1 2
(5/ 4)
The maximum charge in a room shall be in accordance with the following:m= 2 5 x (LFL) x h
ma x
1/ 2
x ( )A
The required minimum floor area Amin to install an appliance with refrigerant charge M (kg)
(5/ 4) 2
shall be in accordance with following: A = ( / (2 5 x (M LFL) x h))
mi n
Where:
m is the allowable maximum charge in a room, in kg;
ma x
M is the refrigerant charge amount in appliance, in kg;
Amin is the required minimum room area, in m2;
2
A is the room area, in m ;
3
LFL is the lower flammable limit, in kg/m ;
h is the installation height of the appliance,in meters for calculating m or A, 1 8 m for wall
ma x m i n
mounted;
Table GG.1 - Maximum charge (kg)
Category
R290 0.038
R32 0.306
LFL
3
(kg/m )
h0
(m)
2
Floor area (m )
0.6 0.05 0.07 0.08 0.1 0.11 0.14 0.18
4 7 10 15 20 30 50
1 0.08 0.11 0.13 0.16 0.19 0.2 0.3
1.8 0.15 0.2 0.24 0.29 0.34 0.41 0.53
2.2 0.18 0.24 0.29 0.36 0.41 0.51 0.65
0.6 0.68 0.9 1.08 0.32 1.53 1.87 2.41
1 1.14 1.51 1.8 2.2 2.54 3.12 4.02
1.8 2.05 2.71 3.24 3.97 4.58 5.61 7.254
2.2 2.5 3.31 3.96 4.85 5.6 6.86 8.85
2
Table GG.2 - Minimum room area (m )
Category
R290 0.038
R32 0.306
LFL
3
(kg/m )
h0
(m)
Charge amount (M) (kg)
2
Minimum room area (m )
0.152kg 0.228kg 0.304kg 0.456kg 0.608kg 0.76kg 0.988kg
0.6 82 146 328 584 912 1514
1 30 53 118 210 328 555
1.8 9 16 36 65 101 171
2.2 6 11 24 43 68 115
1.224kg 1.836kg 2.448kg 3.672kg 4.896kg 6.12kg 7.956kg
0.6 29 51 116 206 321 543
1 10 19 42 74 116 196
1.8 3 6 13 23 36 60
2.2 2 4 9 15 24 40
Tuotetiedot
Merkki: | TCL |
Kategoria: | Ilmanpuhdistin |
Malli: | Gentle Cool S12P6S0T |
Tarvitsetko apua?
Jos tarvitset apua merkille TCL Gentle Cool S12P6S0T esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Ilmanpuhdistin TCL Käyttöohjeet
23 Tammikuuta 2025
23 Tammikuuta 2025
23 Tammikuuta 2025
22 Tammikuuta 2025
20 Lokakuuta 2024
Ilmanpuhdistin Käyttöohjeet
- Ilmanpuhdistin EMOS
- Ilmanpuhdistin IKEA
- Ilmanpuhdistin Aiwa
- Ilmanpuhdistin Aconatic
- Ilmanpuhdistin Trebs
- Ilmanpuhdistin Lenoxx
- Ilmanpuhdistin Arovec
- Ilmanpuhdistin Bionaire
- Ilmanpuhdistin Haus & Luft
- Ilmanpuhdistin Electrolux
- Ilmanpuhdistin Perfect Aire
- Ilmanpuhdistin Alen
- Ilmanpuhdistin Kaysun
- Ilmanpuhdistin Dri Eaz
- Ilmanpuhdistin Rikon
Viimeisimmät Ilmanpuhdistin Käyttöohjeet
9 Huhtikuuta 2025
9 Huhtikuuta 2025
7 Huhtikuuta 2025
6 Huhtikuuta 2025
5 Huhtikuuta 2025
3 Huhtikuuta 2025
3 Huhtikuuta 2025
1 Huhtikuuta 2025
1 Huhtikuuta 2025
31 Maaliskuuta 2025