Protector C11-L Käyttöohje
Protector Kaasunilmaisin C11-L
Lue alta 📖 käyttöohje suomeksi merkille Protector C11-L (4 sivua) kategoriassa Kaasunilmaisin. Tämä opas oli hyödyllinen 52 henkilölle ja sai 4.0 tähden keskimäärin 9 käyttäjältä
Sivu 1/4

BATTERYPOWEREDCARBONMONOXIDE
ALARMC11-L
1MAINFEATURES:
1.Highaccuracyandsensitivity
2.Goodanti-jammingcapability
3.Reliablestabilityandreproducibility
4.LEDdisplayCOconcentration(3digitals)
5.Lowquiescentcurrent(≤20uA),energy-saving,longstandbytime
6.ThreeLEDstoindicatedierentstatus:power(green),alarm(red),
fault(yellow)
7.Easyinstallation,portable,idealforhomeandtravel
8.Test/Mutefunction/ManualReset
9.MemoryFunction
10.Lowbatterywarning
11.Sensorfaultsignalwarning
12.Batteryremovalwarning
13.Endofalarmlifewarning
Thisinstructionleaetcontainsimportantinformationonthe
correctinstallationandoperationofyourcarbonmonoxidealarm.
Readthisleaetfullybeforeattemptinginstallationandretainfor
futurereference.
2.SPECIFICATION
PowerSource:2pcsLR03sizeAAA1.5VPAIRDEERbattery
SensorType:Electrochemical
TypeofGassensed:CarbonMonoxide
Alarmactivation:30to49ppm(aer120minutes)
50ppmto99ppm(60to90minutes)
100ppmto299ppm(10to40minutes)
Above300ppm(0to180seconds)
OperationTemperature:-10to40℃℃
AmbientHumidity:15%to90%
HornLevel:85dBat1m(3.3feet)
ProductWeight:99gapprox
ProductSize:98mmx60mmx29mm
ProductLife:10years
3.WHATISCARBONMONOXIDE
CarbonMonoxide(CO)isaninsidiouspoisonthatisreleasedwhenfuels
areburnt.Itisacolourless,odourless,tastelessgasandthereforevery
diculttodetectwiththehumansenses.COkillshundredsofpeople
eachyearandinjuresmanymore.Itbindstothehemoglobininthe
bloodandreducestheamountofoxygenbeingcirculatedinthebody.In
highconcentrations,COcankillinminutes.COisproducedbythe
incompletecombustionoffuelssuchaswood,charcoal,coal,heatingoil,
paran,petrol,naturalgas,propane,butaneetc.
ExamplesofCOsources:
Runningengineingarage-Gasappliances
OilandGasfurnaces-Portablegenerators
Woodstoves-Gasorkeroseneheaters
BarbecuesCloggedchimneys
WoodandgasreplacesHeatingboiler
4.SYMPTOMSOFCOPOISONING
ThefollowingsymptomsmayberelatedtoCOpoisoning:
35ppmThemaximumallowableconcentrationforcontinuous
exposureforhealthyadultsinany8hourperiod.
200ppmSlightheadaches,fatigue,dizziness,nauseaaer2-3hours
400ppmFrontalheadacheswithin1-2hours,lifethreateningaer3
hours
800ppmDizziness,nauseaandconvulsionswithin45minutes.
Unconsciousnesswithin2hours,Deathwithin3hours.
1600ppmHeadache,dizzinessandnauseawithin20minutes.Death
within1hour
6400ppmHeadache,dizzinessandnauseawithin1-2minutes.
WARNING:Theapparatusmaynotpreventthechroniceectsof
carbonmonoxideexposure,andthattheapparatuswillnotfully
safeguardindividualsatspecialrisk.Itmaynotfullysafeguard
individualswithspecicmedicalconditions.Ifindoubt,consultamedical
practitioner.
5.LOCATINGTHECOALARM
C11-LCarbonMonoxidealarmisdesignedtodetectthetoxicCOfumes
thatresultfromincompletecombustion,suchasthoseemittedfrom
appliances,furnaces,replaceandautoexhaust.
NOTE:Formaximumprotectionanalarmshouldbettedinornear
everyroomthatcontainsafuel-burningappliancesuchasanygasres,
centralheatingboilers,room
heaters,waterheaters,cookers,grills,etc.
WARNING:Thisalarmwillonlyindicatethepresenceofcarbon
monoxidegasatthesensor.Carbonmonoxidegasmaybepresentin
otherareas.
ACARBONMONOXIDEALARMDOESNOTFUNCTIONASA
REPLACEMENTFORASMOKEORGASDETECTOR.
6.Locationofthecarbonmonoxidedetector
6.1General
Thedesignandlayoutofdomesticpremisesandthenumber,typeand
positionofcarbonmonoxidesourcesvarywidely.However,general
guidanceisgivenonwhereandwherenottolocatetheapparatusin
ordertominimisetheriskofmisleadingindications.
6.2Whichroom?
Ideally,anapparatusshouldbeinstalledineveryroomcontainingafuel-
burningappliance.Additionalapparatusmaybeinstalledtoensurethat
adequatewarningisgivenforoccupantsinotherrooms,bylocating
apparatusin:
•remoteroomsinwhichtheoccupant(s)spendconsiderabletimewhilst
awakeandfromwhichtheymaynotbeablehearanalarmfrom
apparatusinanotherpartofthepremisesand
•everysleepingroom
•However,ifthereisafuelburningapplianceinmorethanonerooman
thenumberofapparatusislimited,thefollowingpointsshouldbe
consideredwhendecidingwherebesttoputtheapparatus:
•locatetheapparatusinaroomcontainingauelessoropen-ued
appliance,and
•locateapparatusinaroomwheretheoccupant(s)spendmosttime.
Ifthedomesticpremisesisabedsit(asingleroomservingasbothsitting
andbedroom)thentheapparatusshouldbeputasfarfromthecooking
appliancesaspossiblebueneartowherethepersonsleeps.
Iftheapplianceisinaroomnotnormallyused(forexampleaboiler
room),theapparatusshouldbeputjustoutsidetheroomsothatthe
alarmmaybeheardmoreeasily.Alternatively,aremotealarmsirenmay
beconnectedtoatypeAapparatuslocatedinaroom(s)containinga
fuel-burningappliance.
6.3Whereintheroom?
Itshouldbepossibletoviewallthelightindicatorswheninthevicinity
ofthechosenlocationfortheapparatus.
Itisnotpossibletogivespecicguidanceontheexactlocationofa
detectorwhichsuitsalltypesofroomandtheirusage.Thefollowing
pointsshouldbetakenintoconsiderationwhendeterminingan
optimumlocationforanyappropriatesituation.
6.3.1Wherenottoinstalltheapparatus
Theapparatusshouldnotbeinstalled:
•inanenclosedspace(forexampleinacupboardorbehindacurtain)
•whereitcanbeobstructed(forexamplebyfurniture)
•directlyaboveasink
•nexttoadoororwindow
•nexttoanextractorfan
•nexttoanairventorothersimilarventilationopenings
•inanareawherethetemperaturemaydropbelow-10°Corexceed
40°C,unlessitisdesignedtodoso
•wheredirtandustmayblockthesensor
•inadamporhumidlocation
•intheimmediatevicinityofthecookingappliance
6.3.2Apparatuslocatedinthesameroomasafuel-burning
appliance
Iftheapparatusislocatedonawall:
a)itshouldbelocatedclosetotheceiling;
b)itshouldbelocatedataheightgreaterthantheheightofanydooror
window.
Aceilingmountedapparatusshouldbeatleast300mmfromanywall,
andforawallmountedapparatusitshouldbeatleast150mmfromthe
ceiling.Theapparatusshouldbeatahorizontaldistanceofbetween1m
and3mfromthepotentialsource.
Ifthereisapartitioninaroom,theapparatusshouldbelocatedonthe
samesideofthepartitionasthepotentialsource.
CarbonMonoxidealarmsinroomswithslopedceilingsshouldbe
locatedatthehighsideoftheroom.
WARNING:Thiscarbonmonoxidealarmisdesignedforindooruseonly.
Donotexposetorainormoisture.Itwillnotprotectagainsttheriskof
carbonmonoxidepoisoningwhenthebatteryhasdrained.Donotopen
ortamperwiththealarmasthiscouldcausemalfunction.
7.INSTALLINGTHECOALARM
WARNING:Theapparatusshouldbeinstalledbyacompetentperson.
ThisCOalarmispoweredbybatteryandrequiresnoadditionalwiring.It
caneitherbeinstalledonthewallusingthexingsprovidedorona
tabletop.
7.1WallMountInstallation:
Havingestablishedthemountinglocationensurethatthereisno
electricalwiringorpipeworkintheareaadjacenttothemounting
surface(g1).
Markthetwomountingholelocations.
Drillholesinthepositionsmarked.
Screwtightthescrewsintothedrilledholes,andkeepthesteelscrews
outfor4mm.
Insert2pcsLR03sizeAAA1.5Vbatteriesrmlyintobatterycompartment
ontherearofthedetector.
7.2TabletopInstallation:
JustplacetheCOalarmonthetable,sothattheuserscanseeLEDS
clearly.
WARNING:Installationoftheapparatusshouldnotbeusedasa
substituteforproperinstallation,useandmaintenanceoffuelburning
appliancesincludingappropriateventilationandexhaustsystems.
8.OPERATINGYOURCOALARM
8.1Installbatteries
Thisalarmispoweredby2pcsLR6sizAAA1.5Vbattery,openthebattery
compartmentontherearofthedetectorandinstallthebatteries(seeg
2-5).PAYATTENTIONTOTHEPOLARITYCONNECTIONANDCLOSETHE
BATTERYCOMPARTMENT.
8.2Warmup
Aerthebatteriesareinstalled,thegreen,yellowandredlightsofthe
productareilluminatedinturn,andthenenterthepreheating
countdown,andthewarm-uptimeis120s.
8.3Standbymode
Whennocarbonmonoxideispresent,thegreenLEDashesonceabout
EVERY59SECONDS(seeg6).
8.4TestyourCOalarm
PresstheTESTbuttontoenterthetestmode.Atthistime,thegreen
andyellowlightsarealwayson,theredlightisashing,andtheproduct
simulatesanalarm(seeg7).
NOTE:Thoughthisalarmcanself-diagnosetheamplifyingcircuitand
sensor,itisrecommendedthatyoutestyourCOalarmonceamonthto
ensurethealarmisworkingcorrectly.
8.5Mutefunction
8.5.1EntryCondition
a)Inthealarmstate,iftheconcentrationislowerthan50PPM,pressthe
testbutton(seeFigure8),itwillenterthealarmmutemode,thered
LEDandthegreenLEDwillashonceevery10seconds.
Fig.1
C11-L
Fig.2
Fig.3
Fig.4
Fig.5
Fig.6
Fig.7
Flashesevery59Seconds
C11-L
C11-L
Tuotetiedot
| Merkki: | Protector |
| Kategoria: | Kaasunilmaisin |
| Malli: | C11-L |
Tarvitsetko apua?
Jos tarvitset apua merkille Protector C11-L esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Kaasunilmaisin Protector Käyttöohjeet
12 Joulukuuta 2024
Kaasunilmaisin Käyttöohjeet
Viimeisimmät Kaasunilmaisin Käyttöohjeet
26 Joulukuuta 2024
26 Joulukuuta 2024
15 Lokakuuta 2024
15 Lokakuuta 2024