Optex FTN-AM Käyttöohje

Lue alta 📖 käyttöohje suomeksi merkille Optex FTN-AM (8 sivua) kategoriassa Ei luokiteltu. Tämä opas oli hyödyllinen 38 henkilölle ja sai 4.9 tähden keskimäärin 19.5 käyttäjältä

Sivu 1/8
< CONTENTS >
< FEATURES >
Multilingual instructions
Visit to the Web site to find
valious language versions.
https://navi.optex.net/manual/08697/
EN-1
EN
INSTALLATION INSTRUCTIONS
fit
fit
FTN-ST Standard model with 2 PIRs
FTN-AM FTN-ST with anti-masking
Compact outdoor
detector
Compact outdoor
detector
series
series
WIRED MODEL
Compact design
190° adjustable bracket
Intelligent AND logic
Digital anti-masking (AM model)
Wall tamper (option)
1 INTRODUCTION
1-1 BEFORE INSTALLATION ...................................... 1
1-2 PARTS IDENTIFICATION...................................... 2
1-3 DETECTION AREA................................................ 2
2 INSTALLATION
2-1 INSTALLATION...................................................... 3
3 WALK TEST
3-1 WALK TEST ........................................................... 5
4 DIP SWITCH SETTING
4-1 LED ........................................................................ 5
4-2 ALARM OUTPUT ................................................... 5
4-3 PIR SENSITIVITY .................................................. 5
4-4 ANTI-MASKING...................................................... 6
5 OTHERS
5-1 WALL TAMPER (OPTION) CONNECTION ........... 6
5-2 EXAMPLE OF EOL WIRING.................................. 7
5-3 LED LIGHT PATTERN ........................................... 7
6 SPECIFICATIONS
6-1 SPECIFICATIONS.................................................. 8
6-2 DIMENSIONS......................................................... 8
The check
mark indicates recommendation.
The nix
sign indicates prohibition.
Warning
Caution
Failure to follow the instructions provided with this indication and improper handling may cause
death or serious injury.
Failure to follow the instructions provided with this indication and improper handling may cause
injury and/or property damage.
Warning
Caution Caution
Do not remove the PCB.
ON
2 3 4
1
0.8 to 1.2 m
(2.6 to 3.9 ft.)
Parallel
Mounting height.
Tilt
Keep the detector parallel to the ground.
Consider the direction of the intruder,
for the setting of the detection area.
Do not touch the PCB except for the
DIP switch.
1
INTRODUCTION
1-1
BEFORE INSTALLATION

Tuotetiedot

Merkki: Optex
Kategoria: Ei luokiteltu
Malli: FTN-AM

Tarvitsetko apua?

Jos tarvitset apua merkille Optex FTN-AM esitä kysymys alla ja muut käyttäjät vastaavat sinulle