Midea MFCA26VA-W Käyttöohje
Midea
Ilmastointi
MFCA26VA-W
Lue alta 📖 käyttöohje suomeksi merkille Midea MFCA26VA-W (52 sivua) kategoriassa Ilmastointi. Tämä opas oli hyödyllinen 16 henkilölle ja sai 3.8 tähden keskimäärin 8.5 käyttäjältä
Sivu 1/52

MODEL NUMBER:
MFCA26VA-N
MFCA35VA-N
MFCA50VA-N
MFCA70VA-N
USER MANUAL
Room Air Conditioner
Download the app
& activate product
MSmartHome
Warning notices: Before u nsi g this product, please rea h ma ad t is nu l and SAFETY
MANUA any)L(if carefully and kee forp it future reference. The de n sig and
specifications are ubje s ct to hange w hou c it t prior notice for product improvement.
Consu th your dealer or manufalt wi cturer for eta d ils.
The diagram above is just for reference. Please take the appearanc oe f the a ual ct
produ standard.ct as the

THANK YOU LETTER
Thank you for choosing Midea! Before using your new Midea product, please
read this manual thoroughly to ensure that you know how to operate the
features and functions that your new appliance oers in a safe way.
01
CONTENTS
01
02
06
07
08
10
21
30
26
32
33
35
35
41
50
56
61
61
58
62
34
THANK YOU LETTER
SAFETY PRECAUTIONS
SPECIFICATIONS
PRODUCT OVERVIEW
PRODUCT INSTALLATION
Install Your Indoor Unit
Install Your Outdoor Unit
Refrigerant Piping Connection
Air Evacuation
Electrical And Gas Leak Checks
Test Run
Packing And Unpacking The Unit
OPERATION INSTRUCTIONS
Indoor Unit Display
Remote Control Operation
App Setup And Operation
CARE AND MAINTENANCE
TROUBLESHOOTING
TRADEMARKS, COPYRIGHTS AND LEGAL STATEMENT
DISPOSAL AND RECYCLING
DATA PROTECTION NOTICE

02
It’s really important you read Safety Precautions Before Operation and Installation
Incorrect installation due to ignoring instructions can cause serious damage or injury.
The seriousness of potential damage or injuries is classified as either a WARNING
or CAUTION.
SAFETY PRECAUTIONS
Read these operating instructions carefully and attentively before using/commis-
sioning the unit and keep them in the immediate vicinity of the installation site or
unit for later use!
Warning of electrical voltage
This symbol indicates that there is a danger to life and health of
persons due to voltage.
Warning
The signal word indicates a hazard with a medium level of risk
which, if not avoided, may result in death or serious injury.
Caution
The signal word indicates a hazard with a low degree of risk which,
if not avoided, may result in minor or moderate injury.
Attention
The signal word indicates important information (e.g. damage to prop-
erty), but not danger.
Observe instructions
This symbol indicates that a service technician should only operate and
maintain this appliance in accordance with the operating instructions.
Explanation of Symbols
WARNING
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children shall not play
with the appliance. Cleaning and user maintenance shall not be made by children
without supervision(European Union countries).
This appliance is not intended for use by persons(including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by
a person responsible for their safety. Children should be supervised to ensure that
they do not play with the appliance.

05
Turn o the air conditioner and disconnect the power if you are not going to use
it for a long time.
Turn o and unplug the unit during storms.
Make sure that water condensation can drain unhindered from the unit.
Do not operate the air conditioner with wet hands. This may cause electric shock.
Do not use device for any other purpose than its intended use.
Do not climb onto or place objects on top of the outdoor unit.
Do not allow the air conditioner to operate for long periods of time with doors or
windows open, or if the humidity is very high.
●
●
●
●
●
●
●
Do not clean the air conditioner with combustible cleaning agents. Combustible
cleaning agents can cause fire or deformation.
Turn o the device and disconnect the power before cleaning. Failure to do so
can cause electrical shock.
Do not clean the air conditioner with excessive amounts of water.
●
●
●
CAUTION
CLEANING AND MAINTENANCE WARNINGS
●
●
●
●
●
Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)
This air-conditioning unit contains fluorinated greenhouse gasses. For specific
information on the type of gas and the amount, please refer to the relevant label
on the unit itself or the “Owner's Manual - Product Fiche ” in the packaging of the
outdoor unit. (European Union products only).
Installation, service, maintenance and repair of this unit must be performed by a
certified technician.
Product uninstallation and recycling must be performed by a certified technician.
For equipment that contains fluorinated greenhouse gases in quantities of 5
tonnes of CO2 equivalent or more, but of less than 50 tonnes of CO2 equivalent,
If the system has a leak-detection system installed, it must be checked for leaks at
least every 24 months.
When the unit is checked for leaks, proper record-keeping of all checks is strongly
recommended.
●
●
●
●
●
●
WARNING FOR USING R32/R290 REFRIGERANT
2
2
2
2
2
When flammable refrigerant are employed, appliance shall be stored in a well -
ventilated area where the room size corresponds to the room area as specifiec
for operation.
For R32 frigerant models:
Appliance shall be installed, operated and stored in a room with a floor area larger
than 4m .
For R290 refrigerant models, appliance shall be installed, operated and stored in a
room with a floor area larger than:
<=2.6kW units: 17.33m
>2.6kW and <=3.5kW units: 25.4m
>3.5kW and <=5.2kW units: 34.67m
>5.3kW and <=7.1kW units: 47.33m
Reusable mechanical connectors and flared joints are not allowed indoors.
When mechanical connectors are reused indoors, sealing parts shall be renewed.
When flared joints are reused indoors, the flare part shall be re-fabricated.
Mechanical connectors used indoors shall comply with ISO 14903.

06
SPECIFICATIONS
MFCA26VA-N
MFCA26VA-W
Product Model
Power source
Cooling capacity
Heating capacity
Rated current
Rated power input
Outdoor unit
resistance class
2.60kW
2.65kW
11.0A
2350W
MFCA35VA-N
MFCA35VA-W
3.55kW
3.60kW
11.0A
2350W
220-240V~ 50Hz, 1Ph
IPX4
MFCA50VA-N
MFCA50VA-W
5.20kW
5.20kW
17.5A
3950W
MFCA70VA-N
MFCA70VA-W
7.00kW
8.0 kW5
17.5A
3950W

Gloves Screwdriver &
wrench
Hammer
drill
Core drill Goggles & masks Vinyl tape
It would be perfect you had these tools
07
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may
be slightly dierent. The actual shape shall prevail.
NOTE ON ILLUSTRATIONS:
PRODUCT OVERVIEW
Wall Mounting Plate
(1) (2)
Power Cable(some units)
Refrigerant Piping
Signal Cable
Remote Controller
Drainage Pipe
Louver
Remote controller Holder
(some units)
Functional Filter (On Back of
Main Filter - Some Units)
Front Panel
Outdoor Unit Power Cable
(some units)
1
2
3
4
5
7
8
Fresh air pipe6
9
10
11
12
10 11
3
6
7
8
9
12
1
5
2
4
Air-break
switch
3
1
5
6
7
9
8
12
2
4

09
INSTALLATION SUMMARY - INDOOR UNIT
Drill Wall Hole
Mount Indoor Unit
Wrap Piping and Cable
Connect Piping
Prepare Drain Hose
Connect Wiring
4 5 6
7
9
8
Select Installation Location
1
Determine Wall Hole Position
2
Attach Mounting Plate
3
120mm
(4.75in)
120mm
(4.75in)
150mm (5.9in)
≥
≥
≥
≥
2300mm(depend on actual situation)
( 90.55in)

Before installing the indoor unit, refer to the label on the product box to make sure that the
model number of the indoor unit matches the model number of the outdoor unit.
The following are standards that will help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
Good air circulation Convenient drainage Noise from the unit will not
disturb other people.
Firm and solid—the location will not vibrate
Strong enough to support the weight of the
unit
A location at least one meter from all other
electrical devices (e.g., TV, radio, computer)
DO NOT install unit in the following locations:
Near any source of heat, steam, or
combustible gas
Near flammable items such as curtains or
clothing
Near any obstacle that might block air
circulation
Near the doorway
In a location subject to direct sunlight
Install Your Indoor Unit
Select installation location
1
10
NOTE
NOTE: FOR PRODUCT INSTALLATION
: PRIOR TO INSTALLATION
If there is no fixed refrigerant piping:
While choosing a location, be aware that you should leave ample room for a wall hole (see
Drill wall hole for connective piping step) for the signal cable and refrigerant piping that
connect the indoor and outdoor units. The default position for all piping is the right side of
the indoor unit (while facing the unit). However, the unit can accommodate piping to both
the left and right.
Tuotetiedot
Merkki: | Midea |
Kategoria: | Ilmastointi |
Malli: | MFCA26VA-W |
Tarvitsetko apua?
Jos tarvitset apua merkille Midea MFCA26VA-W esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Ilmastointi Midea Käyttöohjeet
12 Maaliskuuta 2025
12 Maaliskuuta 2025
12 Maaliskuuta 2025
12 Maaliskuuta 2025
12 Maaliskuuta 2025
17 Helmikuuta 2025
12 Helmikuuta 2025
12 Helmikuuta 2025
12 Helmikuuta 2025
11 Helmikuuta 2025
Ilmastointi Käyttöohjeet
- Ilmastointi Einhell
- Ilmastointi Sheffield
- Ilmastointi Aconatic
- Ilmastointi Kelvinator
- Ilmastointi Woods
- Ilmastointi Argoclima
- Ilmastointi Mistral
- Ilmastointi Khind
- Ilmastointi CyberPower
- Ilmastointi Broan
- Ilmastointi Svan
- Ilmastointi Keystone
- Ilmastointi NewAir
- Ilmastointi Philco
- Ilmastointi Candy
Viimeisimmät Ilmastointi Käyttöohjeet
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025