1. , .ThisdocumentisforquickinstallationguidanceonlypleaserefertoUserManualformoredetails
2. .Growattshallnotbeliableforanydamageresultingfromunproperinstallation
Note:
MID 17-40KTL3-X Quick Guide
Note:
1.When drilling holes in the wall, avoid water and electricity pipes, otherwise it may cause danger.
Overview
Installation
System overview
2.1 Installation requirements
2.2 Wall mounting
23.Communication module installation
Inverterside
Inverterside
Inverterside
Inverterside
▲Up
UninstallInstall
3
3
3
33.
.
.
..
Electrical connection
Please prepare the cable before connecting as follows.
1
2
3
4
Cable name
PV input wire
Type
four or five polychromatic
multi-core copper wires
PVwiresuch as PV1F(-)
RS485
Recommendmodel
16mm² - 20mm²
16mm² - 20mm²
4mm- 6mm² ²
/
No.
Communicatio
wire
AC output wire
grounding wire
Protective
Single multi-core
yellow-green wire
1.Please make sure all switches are in “OFF”
position before wiring. For personal safety,
please do not operate with electricity.
2.If the diameter of the cable does not match
the terminal, or the cable is aluminum wire,
please contact our after-sales personnel.
Note:
31. Grounding
Connect to the inverter
side.
It is recommended to use 16-20mm²
cable.
Install the AC side water
proof cover.
32 .AC output connection
PE
inverter side
10-12mm
33. DC connection
3.3.1 PV input terminal installation
230
218
579
240133
433
237
≥500mm
≥300mm
≥500mm
≥500mm
Noted:Waterproof must be blocked
with fireproof mud to prevent water.
Keep the
bracket
installed
horizontally.
810mm-
1
2
3
4
5
4mm- 6mm² ²
4mm- 6mm² ²
Positive metal terminal
Positive metal terminal
Negative metal terminal
Negative metal terminal
Negative metal terminal
Please make sure the cable can not be
pulled out after pressing.
Pull the PV cable make sure there
is no loose or shaking.
Make sure the cable polarity is
correct and voltage is less than
1100V.
1
5
6
7
81112109
2
3
4
Tuotetiedot
| Merkki: | Growatt |
| Kategoria: | Ei luokiteltu |
| Malli: | MID 17-40KTL3-X |
Tarvitsetko apua?
Jos tarvitset apua merkille Growatt MID 17-40KTL3-X esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Ei luokiteltu Growatt Käyttöohjeet
30 Maaliskuuta 2025
10 Helmikuuta 2025
26 Joulukuuta 2024
26 Joulukuuta 2024
17 Joulukuuta 2024
17 Joulukuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
Ei luokiteltu Käyttöohjeet
Viimeisimmät Ei luokiteltu Käyttöohjeet
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025