A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o
SequenceD Power DiStro, 120A
ASD-120
Ac DiStro’S

A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o
1
reAD thiS FirSt!
IMPORTANT: DO NOT RACKMOUNT THIS UNIT UNTIL ALL JUMPERS AND
WIRING HAVE BEEN INSTALLED. MANY INSTALLATIONS WILL REQUIRE
TEMPORARILY REMOVING THE TOP COVER FOR ADJUSTMENTS.
The instructions provided in this manual are insufficient for completing a working ASD-
120 installation. While the subject of attaching a supply cable to the ASD-120 is covered, the connection
of the far end (pigtail end) of that cable to a power source is not. Because of the many congurations that
120 amp or larger electrical services can take and the numerous connector types that may be used, it is not
possible to adequately describe every situation that may be encountered. Therefore, it is strongly rec-
ommended that the selection of the ASD-120 supply cable, and the connections to both
ends of it, be done by a licensed electrician who is familiar with the available electrical
service. Wiring of electrical input is covered
on pages 6 though 8.
TO CHANNEL-1
OF COMPUTER
CONTROLLER
OR POWERLINK
TO CHANNEL-2
OF COMPUTER
CONTROLLER
OR POWERLINK
STATUS
START
REM
FORCE
ON
REM
COM
GND
RELAY
COM
F
B
C
D
E
+12V
FORCE
OFF
A
ON
OFF
LATCHING (MAINTAINED)
REMOTE SWITCH*
* SUCH AS THE FURMAN RS-1 ** SUCH AS THE FURMAN RS-2
STATUS
START
REM
FORCE
ON
REM
COM
GND
RELAY
COM
MOMENTARY
REMOTE SWITCHES**
F
B
C
D
E
+12V
FORCE
OFF
A
STATUS
START
REM
FORCE
ON
REM
COM
GND
RELAY
COM
F
B
C
D
E
+12V
FORCE
OFF
A
STATUS
START
REM
FORCE
ON
REM
COM
GND
RELAY
COM
F
B
C
D
E
+12V
FORCE
OFF
A
ASD-120 Master ASD-120 Slave
THIS JUMPER MUST BE
INSTALLED FOR THE ASD-120
SWITCHING TO FUNCTION
THIS JUMPER MUST BE
INSTALLED FOR THE ASD-120
SWITCHING TO FUNCTION
THIS JUMPER MUST BE
INSTALLED FOR THE ASD-120
SWITCHING TO FUNCTION
THIS JUMPER MUST BE
INSTALLED FOR THE ASD-120
SWITCHING TO FUNCTION
EMPLOYING TWO OR MORE ASD-120’s.
SWITCHING/SEQUENCING CONNECTIONS FOR ASD-120
Congratulations on your purchase of a Furman ASD-120 Sequenced Power Distro. Please read
this manual completely before installing your ASD-120, or at the very least review the quick start
pages.
quicK StArt

A S D - 1 2 0 – S e q u e n c e D P o w e r D i S t r o
ASD-120
PS-REL
AVIS:
RISQUE DE CHOC
ELECTR IQUE -- NE
PAS OUV RIR
120 V AC
60 HZ
15A
LOAD
MAX
120 V AC
60 HZ
15A
LI S TE D
7Z 3 7
PR O F ES S IO NA L
AU D IO E QU IP M EN T
ÆÆ
UNSWITCHED
DELAY 1
DELAY 2
DELAY 3
+12V
STAT
REM
CLASS 1
WIRING
RISK OF ELECT RIC
SHOCK. DO NOT
OPEN. R EFER
SERV ICING TO
QUALIFIE D SERV ICE
PERSONNE L.
TO RE DUCE THE
RISK OF FIRE OR
ELECTR IC SHOCK
DO NOT EXPOS E
THIS E QUIPMENT TO
RAIN AND MOISTURE .
CAUTION!
GND
15
PS-8R or PS-PRO DELAY 3
SCENARIO - 2 TYPICAL PROFESSIONAL INSTALLATION
REMOTE ASD-120 TRIGGERED BY HOUSE PS-8R, PS-PRO ACTIVATED BY PS-REL
WITH THIS WIRING CONFIGURATION
THE ASD-120 WILL BE IN A FIXED OFF
POSITION IF T HE CONNECTION IS BROKEN
THIS JUMPER MUST BE INSTALLED
FOR THE ASD-120 SWITCHING TO FUNCTION
+12V
STATUS
START
REM
FORCE
ON
FORCE
OFF
REM
COM
GND
COM
F
A
B
C
D
E
C NO NC
+12V
S TATUS
S TART
R EM
F OR CE
ON
F OR CE
OFF
R EM
C OM
G ND
C OM
F
A
B
C
D
E
ASD-120
C NO NC
P S-RE L
AVIS:
R IS QUE DE C HOC
E LE CTRIQU E --NE
PAS OUVR IR
120 VAC
60 HZ
15A
LOAD
MAX
120 VAC
60 HZ
15A
L IS TE D
7 Z37
P RO FE S S IO NA L
A UD IO EQ UI PM EN T
ÆÆ
UNS WITC HE D
DEL AY 1
DEL AY 2
DEL AY 3
+12V
S TAT
R EM
C LASS 1
WIR ING
R IS KOF E LECTRIC
S HOCK. DO NOT
OPE N. RE FER
S ER VICING TO
QUALIFIE D SERVIC E
PER S ONN EL.
TO R EDUCE THE
R IS KOF F IRE OR
E LE CTRIC S HOCK
DO NOT EXPO SE
THIS E QUIPMENT TO
R AIN AND MOIS TURE .
C AUTION !
G ND
15
P S-8R or PS -P RO DE LAY 3
S CE NARIO - 1 T YP IC AL PR OF ES S IONAL INS TALLAT ION
W ITH THIS W IR ING C ONFIGURATION
T HE AS D-120 W ILL B E IN A FIXE D ON
P OS ITION IF T HE CONNEC TION IS BR OK EN
T HIS J UMPE R MUS T B E INS TAL LED
F OR THE ASD-120 SW ITCHING T O F UNCT IO N
R EMOTE ASD-120 TR IG G ER ED BY HOUS E P S-8R , P S-PR O ACTIVAT ED BY PS -R EL
2
quicK StArt
REMOTE INSTALLATION OF AN ASD-120
Jumper in
maintained
on/default
position
Jumper in
maintained
off position
Change
jumper on
ASD-120
Control
board, see
illustration
on page 4
Tuotetiedot
Merkki: | Furman |
Kategoria: | Ei luokiteltu |
Malli: | ASD-120 2.0 |
Tarvitsetko apua?
Jos tarvitset apua merkille Furman ASD-120 2.0 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Ei luokiteltu Furman Käyttöohjeet
11 Helmikuuta 2025
14 Tammikuuta 2025
8 Tammikuuta 2025
8 Tammikuuta 2025
11 Joulukuuta 2024
11 Joulukuuta 2024
21 Lokakuuta 2024
21 Lokakuuta 2024
19 Lokakuuta 2024
19 Lokakuuta 2024
Ei luokiteltu Käyttöohjeet
- Ei luokiteltu Revlon
- Ei luokiteltu Ansmann
- Ei luokiteltu Forodi
- Ei luokiteltu Em-Trak
- Ei luokiteltu Lexivon
- Ei luokiteltu Eero
- Ei luokiteltu Bosch
- Ei luokiteltu DAP Audio
- Ei luokiteltu Thermaltake
- Ei luokiteltu DoorBird
- Ei luokiteltu MEPROLIGHT
- Ei luokiteltu Pioneer
- Ei luokiteltu Babymoov
- Ei luokiteltu IsoTek
- Ei luokiteltu REMKO
Viimeisimmät Ei luokiteltu Käyttöohjeet
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025