Festo DADG-AK-G8-10-100 Käyttöohje
Sivut 1 Engels
Lue alta 📖 käyttöohje suomeksi merkille Festo DADG-AK-G8-10-100 (1 sivua) kategoriassa Ei luokiteltu. Tämä opas oli hyödyllinen 16 henkilölle.

DADG-AK-G8
Connection set
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Deutschland
+49 711 347-0
www.festo.com
Assembly instructions
8157118
2021-08
[8157120]
Translation of the original instructions
© 2021 all rights reserved to Festo SE & Co. KG
1
Applicable documents
All available documents for the product
è
www.festo.com/sp.
DocumentProductTable of contents
Operating instructionsMini slide DGST–
Tab. 1:
Applicable documents
2
Safety
2.1Safety instructions
–Only mount the product on components that are in a condition to be safely
operated.
–Observe further applicable documents.
–
Observe tightening torques. Unless otherwise specified, the tolerance is ± 10%.
2.2Intended use
Connection of compressed air lines axially at the back of the mini slide DGST.
3Additional information
–
Contact the regional Festo contact if you have technical problems
è
www.festo.com.
–
Accessories and spare parts
è
www.festo.com/catalogue.
4Product Range Overview
4.1Scope of delivery
1
2
3
Fig.1
1
Air through-guide (1x)
2
O-ring (2x)
3
Socket head screw (2x)
4.2Not in scope of delivery
4
5
6
Fig.2
4
Mini slide (1x)
DGST
5
Fitting (2x)
6
Grease (1x)
e.g. LUB-KB1
5Assembly
1
2
A
6
Fig.3
1.
Lightly grease the O-rings with the grease to facilitate assembly.26
2.
Position the O-rings in the slots [A] of the air through-guide .21
The nominal tightening torques are printed on the air through-guide.
Fig. 4:Example: DADG-AK-G8-16
1
3
4
5
B
Fig.5
DADG-AK-G8DGST-
681012162025
3ScrewM3x5M3x8M4x8M5x12M6x12
[Nm]1.01.21.53.05.0
[B]Air connection
thread
M5G⅛
[Nm]0.73.0
Tab. 2:Screw size, tightening torques and air connection thread
1.
Place the air through-guide on the mini slide .14
2.Fasten the air through-guide with the screws to the mini slide .134
3.
Mount the desired fittings on the air connection threads [B].5
Use of one-way flow control valves GRLA on the air connection threads [B]
One-way flow control valves GRLA may restrict the access [C] to the adjustment of
end position on the DGST.
•
Adjust the external end position before mounting the one-way flow control
valves [D].
•Rotate the one-way flow control valves [D] so the access remains clear.
CD
Fig.6
Tuotetiedot
| Merkki: | Festo |
| Kategoria: | Ei luokiteltu |
| Malli: | DADG-AK-G8-10-100 |
Tarvitsetko apua?
Jos tarvitset apua merkille Festo DADG-AK-G8-10-100 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Ei luokiteltu Festo Käyttöohjeet
Festo CRDSNU-B-25-40-PPS-A-MG-A1 Käyttöohje Festo CRDSNU-12-10-P-A Käyttöohje Festo NEBM-L10G14-EH-10-Q6N-LE12 Käyttöohje Festo CRDSNU-20-10-P-A Käyttöohje Festo CRDSNU-B-16-100-P-A-MG-A1 Käyttöohje Festo AKM-25 Käyttöohje Festo DFM-20-B Käyttöohje Festo DFPC-100-100-D Käyttöohje Festo DADM-CK-90-8 Käyttöohje Festo DFPC-125 Käyttöohje
Suosittuja kategoriassa Ei luokiteltu
Festo EADH-E17-MP1 Käyttöohje Festo SFAB-200U-HQ10-2SV-M12 Käyttöohje Festo DGSL-12-20-P1A Käyttöohje