mail@bremsenergie.de, www.bremsenergie.de, mail@brakeenergy.com, www.brakeenergy.com
Dbl--BWD500240FE_deuengl_20210723.docx
Brake resistor BWD500240FE
CACR--0- LE224W500
Description:
Shortprotecting---circuitproof, self
1)
in anodized aluminium casings, protection class according to IP65
2)
, for
operation on converters (brake transistors). For detailed dimensions refer to the technical drawing (on request).
Technical data (ϑ
A
= 20°C,if nothing else is stated):
Nominal capacity (W)
Dimensions LxWxH (mm)
Resistance values (Ohm)
200 (500 at ED = 35%, ϑ
A
= 20°C)
216 x 80 x 15
240
Parameters
Symbol
Value
Unit
Conditions
Tolerance
± 5
%
room temperature
Weight
m
approx 0,55
kg
Connecting wire
A
1,5(AWG16)
mm
2
PTFE isolated, UL Style 1659
L
510±40
mm
Storing temperature
ϑ
S
- 25 ... +85
°C
Max. permissible operating
voltage
U
B
≤ 700 AC
≤
1000 DC
V
considering “self-protection”
1)
U
B
≤ 600 AC
#
*
≤ 8 50DC*
V
considering CSA
#
and UL*
Energy consumption
E
7,5
15
kJ
with 1,2s (1% ED)
with 7,2s (6% ED)
Insulation voltage
U
ISO
≥ 4000
V
AC; f = 50 Hz; t = 1 s
Max. permissible casing
temperature
ϑ
C
≤ 250
°C
free convection
Temperature coefficient
TK
20 ... 100
10
-6
/K
Insulation resistance
R
ISO
≥ 100
M Ω
U
MEAS
= 1000 VDC
Inductance
L
≤ 30
µH
f = 300 kHz, U
MEAS
= 50 mV
Capacity against housing
C
≤ 300
pF
f = 300 kHz, U
MEAS
= 50 mV
Thermic time factor
τ
Approx 550
sec
Casing BWD500xxx
Max. permissible wire temperature
ϑ
hot
max. + 600
°C
Approbation
cCSAus (CSA file# 210040)
cURus (UL file# E233422)
(both based on CSAC22.2 and UL 508)-
1):
Self-protection: : At four time type capacity and free convectionWarning
1. No short circuitMounted in areas without
2. No fault to framefree air change surface
- 3. Selfextinguishingno fire temperatures up to
4. No melting of casing 350 degrees Celsius can
be reached.
2):
Test conditions: Water jet from nozzle 6,3mm inside diameter, flow rate 12,5l/min +/- 5%, water pressure according to volume flow,
distance 2,5-3m, test duration 3min
CACR-LE2-240-W500 | 8164614 [8164616] 2021-08b
Tuotetiedot
| Merkki: | Festo |
| Kategoria: | Ei luokiteltu |
| Malli: | CACR-LE2-240-W500 |
Tarvitsetko apua?
Jos tarvitset apua merkille Festo CACR-LE2-240-W500 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Ei luokiteltu Festo Käyttöohjeet
30 Maaliskuuta 2025
30 Maaliskuuta 2025
30 Maaliskuuta 2025
30 Maaliskuuta 2025
30 Maaliskuuta 2025
30 Maaliskuuta 2025
30 Maaliskuuta 2025
30 Maaliskuuta 2025
30 Maaliskuuta 2025
30 Maaliskuuta 2025
Ei luokiteltu Käyttöohjeet
Viimeisimmät Ei luokiteltu Käyttöohjeet
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025
9 Huhtikuuta 2025