TECHNICAL SPECIFICATIONS
ENDA EPA242 PROGRAMMABLE  AC/DC AMMETER
Read this document carefully before using this device. The guarantee will be expired by damaging of  the device if you don't
attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or
capital disadvantages.
77 x 35mm sized
4 digits display
Easy to use with front panel keypad
Programmable scale between 5A and 9999A
Multifunctional alarm output (NO+NC) for upper and lower limits
Communication feature over isolated RS485, using ModBus RTU protocol ( )
Measuring type can be selected as AC, DC or true RMS
Key lock feature
0-20mA, 4-20mA, 0-10V or 1-5V Output selection (For only “A” type output devices)
CE marked according to European Norms
5A or 60mV, CT20/30 Current Transformer or 60mV input (Specify at Order)
 (Optional)
    Optional
Thank you for choosing    rogrammable  AC/DC  mmeterENDA EPA242 P A
ENVIRONMENTAL CONDITIONS
 Height
 Max. 2000m
80   up to 31Relative humidity for temperatures% °C  decreasing linearly   50% at 40°C., to
 Ambient/stroge temperature
 Max. Relative humidity
0 ... +50°C/-25 ... 70°C
Rated pollution degree
According to EN 60529        Front panel   : IP6     ,     Rear5  panel   : IP20
 Do not use the device in locations subject to corrosive and flammable gases.
Order Code  :  EPA242 -       -    -                      -
1 3 4
2 - Output
     R..........Relay
     A...........Analog Output
     Blank....No Output
4 Isolated ModBus -
RS ...... ModBus
( )
I Isolated
                  Specify at Order .
3 - Supply Voltage
     230VAC...230V AC
     110VAC...110V AC
     24VAC.....24V AC
     SM...........9-30V DC / 7-24V AC
2
1 - Input
     CT.......CT20/30 Current
                Transformer Input or 60mV
     Blank....5A or 60mV
While input type in 5A  /  60mv  ;  =  0A...5A  0A...9999A  ( Determined by   parameter. e.g ; If   , scale is   )c.tr.r c.tr.r 5
  0.002A x      ( e.g ; For  , sensitivity is    )c.tr.r 5 =    0.01Ac.tr.r
  AC
  RMS
  DC
                        1
                        40k
2mΩ
Ω
AC and RMS
DC
%1
±
and
and
12
9
11
10
%1
±
%1
±
and
and
12
9
11
10
While input type in CT20/30 / 60mV ;
 =  0A...300A = 0A...300A
 =  0A...120A = 0A...120A
 =  0A..9999A = 0A...5A
If   , input range is   ( Determined by   parameter.  e.g ;  If         , scale is   )
If   , input range is   ( Determined by   parameter.  e.g ;  If         , scale is   )
If   , input range is   (Determined by   parameter. e.g ;   If         , scale is   )
ityp Ct20 turn turn 1
ityp Ct30 turn turn 1
ityp 5Hnt c.tr.r c.tr.r 5
ELECTRICAL CHARACTERISTICS
 Supply
 Power consumption
 Wiring
 Scale
 EMC
 Safety  equirementsR
 Input Impedance
 Frequency Range
 Input Range
 Sensitivity
 Accuracy
 230V AC +10% -20%, 50/60Hz  or  24V AC   10% , 50/60Hz  or  optional 9-30V DC / 7-24V AC  10% SMPS± ±
Max.  VA5
2.5mm² screw-terminal connections
While input type in 5A  /  60mv  ;  =  -5A...5A  -999A...9999A  ( Determined by   parameter. e.g ; If   , scale is    )c.tr.r c.tr.r 5
While input type in CT20/30 / 60mV ;
 =  0A..9999A = -5A...5A
DC Measurement can not be performed by using current transformer.
If   , input range is    (Determined by   parameter. e.g ;  If         , scale is   )ityp 5Hnt c.tr.r c.tr.r 5
(full scale)    ( For square wave form)± 2%
(full scale)
(full scale)    ( For square wave form)± 2%
                                                      or  CT20/30 input devices  0....150mA-5A...5A
         -60mV...60mV
( Device   10A  current )
( Device   50V   voltage )
  may be damaged at  and above  s
  may be damaged at  and above s
 EN 61326-1: 2013
 EN 61010-1: 20  (Pollution degree 2, overvoltage category II)10
 DC ,  10Hz - 200Hz    ( For square wave form)10Hz - 70Hz
 Mechanical 30.000.000 ; Electrical 100.000 operation.
OUTPUTS
 Alarm output
 Relay: 250V AC, 8A (for resistive load), NO+NC
  Life expectancy for relay
   outputAnalog
0-20mA DC, 4-20mA DC, 0-10V DC   1-5V DC  . ( Ω)or selection Load resistance for current outputs are max. 500
HOUSING
 Housing type
 Suitable for flush-panel mounting. (According to DIN 43 700)
 Dimensions
 W7 xH xD mm7 35 61
 Weight
 Enclosure material
 Self extinguishing plastics.
 Approx.   50g (after packing)2
While cleaning the device, solvents (thinner,  , acid etc.) or corrosive materials must not be used.gasoline
CT20/30 Current Transformer must be ordered separately.
SET
 EPA242
ENDA
OUT         AC         DC         ACDC
A
0.000
english
EPA242-E-290319
1. / 4
E-mail :   info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.:  +49 (0)7451 / 625 617
Fax:  +49 (0)7451 / 625 0650
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
Tuotetiedot
| Merkki: | Enda | 
| Kategoria: | Mittauslaitteet | 
| Malli: | EPA133 | 
Tarvitsetko apua?
Jos tarvitset apua merkille Enda EPA133 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Mittauslaitteet Enda Käyttöohjeet
                        
                         20 Tammikuuta 2025
                        
                    
                                                            
                        
                         18 Tammikuuta 2025
                        
                    
                                                            Mittauslaitteet Käyttöohjeet
- Mittauslaitteet Toolland
- Mittauslaitteet Ebro
- Mittauslaitteet Kyoritsu
- Mittauslaitteet Uni-T
- Mittauslaitteet Tempo
- Mittauslaitteet Vemer
- Mittauslaitteet Chauvin Arnoux
- Mittauslaitteet Metrix
- Mittauslaitteet Senseca
- Mittauslaitteet Noyafa
- Mittauslaitteet Techno Line
- Mittauslaitteet Sonel
- Mittauslaitteet Klein Tools
- Mittauslaitteet TFA
- Mittauslaitteet Ermenrich
Viimeisimmät Mittauslaitteet Käyttöohjeet
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025
                        
                    
                                                            
                        
                         3 Huhtikuuta 2025